Attachment 4 - Decision Notice MCU16 0130

Attached to the e-mail Change to DA - MCU16/0130.01.msg.

of 10

Page text shows just the words. Original shows the document exactly as it was published.

ENGINEERING
      Frontage Works
26.   The existing masonry planter boxes located adjacent to the Eumundi Noosa Road
      frontage must be removed and/or relocated to be wholly within the subject site
      Site Access and Driveways
27.   A sealed access driveway must be provided from Eumundi Noosa Road to all parking
      and manoeuvring areas of the development. The works must be undertaken in
      accordance with an Operational Works approval and must include in particular:
      a.   a new driveway crossover adjacent to the northern site boundary. The driveway
           must be in accordance with Council’s standard drawing number RS-051 and
           located to not interfere with the existing access to the adjoining property.
      b.   the northern driveway must be for left turn entry only.
      c.   the southern driveway must be for left turn exit only.
      d.   internal driveways between the entrance driveway, the carparking areas and the
           exit driveway.
      e.   suitable safety measures, including warning signage, to improve driver awareness
           of pedestrians and enhance pedestrian safety. Warning signage must be provided
           near the exit driveway to warn motorists of pedestrian movement along the
           frontage street.
      Car Parking
28.   A minimum of 16 car parking spaces must be provided and marked on the site and made
      available and accessible at all times while the use is open for business. The works must
      be undertaken in accordance with an Operational Works approval and must include in
      particular:
      a.   pedestrian routes between the carparking area and the business use.
      b.   dimensions, crossfalls and gradients in accordance with Australian Standard
           AS/NZS2890.1:2004: Parking Facilities.
29.   All car parking areas and access driveways must be maintained exclusively for vehicle
      parking and manoeuvring and kept in a tidy and safe condition at all times.
30.   Directional signage must be provided to direct visitors and customers to the car parking
      spaces provided on site.
      Stormwater Drainage
31.   The site must be provided with a stormwater drainage system connecting to a lawful
      point of discharge. The works must be undertaken in accordance with an Operational
      Works approval and be generally in accordance with drawing number 16789-SK001
      Revision A dated 1 February 2017 prepared by TOD Engineers and Project Managers
      Electricity and Telecommunication Services
32.   Unless otherwise stipulated by telecommunications legislation at the time of
      construction, the development must be provided with all necessary conduits, pits and
      pipes to accommodate the future connection of optic fibre technology
      telecommunications.
33.   Certification must be submitted to Council from all relevant service providers which
      certifies that the development has met the requirements of this Decision Notice and all
      applicable legislation at the time of construction.




                                                                                    Page 5 of 10
Log in to download the original file

Attachment 4 - Decision Notice MCU16 0130.pdf · 102 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.