                                ii.    Are provided with a free-draining outlet from the sub-soil drainage system.
                        d.      Incorporation of a primary stormwater quality treatment system for the effective
                                removal of gross pollutants.
                 32.    Permanent educational signage must be erected to educate the customers to the
                        development about the function of the bioretention device(s). The dimensions, standard,
                        presentation and location of the educational signage must be in accordance with an
                        Operational Works approval.
                 33.    All vegetated stormwater quality treatment devices must be maintained in accordance
                        with the Water by Design (2009) Maintaining Vegetated Stormwater Assets (Version 1)
                        and primary treatment devices maintained in accordance with the manufacturer’s
                        recommendations. The approved Operational Works drawings for the stormwater quality
                        treatment system and detailed life cycle costing of the system must be attached as an
                        addendum to this document and kept on site by the operator of the development.
                        Records of all maintenance activities undertaken must be kept and made available to
                        Council upon request.
                 EASEMENTS
                 34.    Unless otherwise agreed in writing by the relevant service provider, any public or third
                        party infrastructure located on the subject site must be placed within an easement
                        registered against the title of the property.
                 35.    All easements must be designed in accordance with the planning scheme and granted
                        at no cost to the Grantee. Where the Grantee is Council or a service authority, the
                        easement documentation must be in accordance with the Grantee’s standard easement
                        terms. Draft easement documentation must be submitted to Council for endorsement.
                 36.    All works must be kept clear of any existing or proposed easements on the subject land,
                        unless agreed otherwise in writing by the Grantee.
                 EARTHWORKS AND RETAINING WALLS
                 37.    All fill and associated batters must be undertaken in accordance with an Operational
                        Works approval and contained entirely within the subject site unless written permission
                        from the respective landowner(s) is provided to Council. The Operational works approval
                        is to be generally in accordance with the Bulk Earthworks Plan C03-001 and Bulk
                        Earthworks Section C03-101 dated 21.02.2023 and prepared by Acor Consultants
                 38.    Design all earth retaining structures within private land in accordance with Australian
                        Standards, Building Code requirements and Noosa Planning Scheme current the time of
                        the operational works application and the following:
                        a.      Earth retaining structures must be certified by a Registered Professional Engineer
                                Queensland (RPEQ) where exceeding 1.0m in height.
                        b.      The minimum design life (the period assumed in design for which a structure or
                                structural element is required to perform its intended purpose without replacement
                                or major structural repairs) for the earth retaining structure that is specified in Table
                                3.1 of Australian Standard AS4678;
                        c.      Earth retaining structures within the land and around areas of cut on or near the
                                boundaries of the site must be designed to allow for live and dead loads associated
                                with the land/premise’s current occupancy use;
                        d.      Where the adjoining land use rights or zoning allows for industrial uses a minimum
                                live load of 25kPA must be allowed in the design of the retaining structure for these
                                adjoining premises.
                        e.      All retaining walls that are publicly accessible and exceed 1.0m in height must be
                                fitted with a commercial grade safety fence.




                                                                                                              Page 7 of 12
Document Set ID: 22640657
Version: 7, Version Date: 02/11/2023

Used in these records

About this file

File size
181 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice - Council Meeting Decision - MCU22 0051 [As Published].pdf · 181 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.