Council archive · source document
Decision Notice - Change to an Existing Approval - 010.2005.00001189.005 [As Published] · 132005.1189.05
2005/1189
35. A new full width concrete or paved path shall be constructed along the Thomas Street and
Gympie Terrace frontages of the site in accordance with Council’s design standards.
Provision shall for street tree planting shall include pedestrian friendly permeable surfaces
2
around the root system of those trees a minimum of 1m . Care shall be taken to protect any
underground services.
36. A pram ramp shall be installed at the roundabout of Gympie Terrace and Thomas Street (on
the Gympie Terrace frontage) in accordance with the Disability Discrimination Act 1992 and
Australian Standard AS1428.1-2001 “Design for access and mobility”.
37. The existing pram ramp in Thomas Street shall be upgraded to comply with the Disability
Discrimination Act 1992 and Australian Standard AS1428.1-2001 “Design for access and
mobility”.
38. All paths and pram ramps shall be designed and constructed to ensure pedestrian safety
using non-slip materials and to produce an evenly graded surface finish.
39. All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel,
footpath paving and landscaping such as trees and grasses in accordance with Council’s
Standard specifications prior to commencement of the use permitted by this permit.
Roadworks Contributions (Local Road Network)
40. A roadworks contribution of $2,145.40 towards safety improvements to Gympie Terrace shall
be paid to the Council prior to obtaining a Development Permit for Operational Works. This
amount will be subject to variations in the Consumer Price Index, All Groups Brisbane from
December 2005 until the date of payment.
Pathway Contributions
41. A pathway contribution of $1,234 towards external major pathways, in accordance with
Planning Scheme Policy PSP41 Coastal Major Pathway Contributions, shall be paid to the
Council prior to obtaining a Development Permit for Operational Works. This amount will be
subject to variations in the Consumer Price Index, All Groups Brisbane from December 2005
until the date of payment.
Undergrounding Power
42. A contribution of one third of the cost of undergrounding the overhead electricity wires to the
Gympie Terrace and Thomas Street frontage of the development shall be paid to Council prior
to commencing the use. Conduits shall be installed along the site’s full frontages to Gympie
Terrace and Thomas Street to the satisfaction of Council and Energex.
Stormwater Drainage
43. All stormwater drainage shall be collected on site and discharged so there is no net increase
in stormwater runoff from the site. Stormwater drainage permitted to drain from the site shall
be discharged to Council’s kerb & channel street drainage system in both Gympie Terrace and
Thomas Street. Plans of the drainage design shall be prepared by a Registered Professional
Civil Engineer and submitted to Council prior to obtaining a Development Permit for
Operational Works.
The maximum discharge of stormwater drainage allowable to Council’s kerb & channel street
drainage system at any one location is 25 litres/second.
44. The existing open concrete channel running along the base of the retaining walls of adjoining
properties on the southern boundary of Lot 2 RP102593 and at the rear boundary of Lots 1&2
RP102594 and Lot 2 RP102593 shall be replaced by piping to drain any areas of the site or
adjoining lots that pond due to proposed filling.
Page 7 of 19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - Change to an Existing Approval - 010.2005.00001189.005 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 97 KB (small file)
- File type