Council archive · source document
Attachment 7 - Flood Impact Assessment - Covey · 132005.638.06
Very large file (68.6 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Table 3-3 - Developed Hydraulic Structures
Type Upstream Downstream
C=circular Invert Level Invert Level Size No. of
ID
R=box culvert (m AHD) (m AHD) (mm) Pipes
DEV01 R 12.310 12.200 2100 x 1500 6
3.14 Developed Case Scenario
The changes to the developed case scenario included:
• A design TIN to represent finished elevation levels for the proposed development site at each
stage of the development. Refer to Figure 2-3 for the developed case topography adopted
for each development stage in the model;
• Added a set of culverts for the road crossing at the existing clean water drain;
• Update the impervious area to represent the proposed development site; and
• Updated Manning’s n roughness coefficients and soil infiltration rates based on values shown
in the developed model Manning’s maps in Appendix B.
Flood Impact Assessment Page 14 of 25
Project No 244035 | Ref No M25-0479Rpt – Issue A – January 2026