Side Boundary Clearance

Northem and southem side, and rear { eastern } boundary clearances are compliant with the
Queensland Development Code Part 12 - Design and Siting Standard :

 

PERFORMANCE CRITERIA

ACCEPTABLE SOLUTION

 

 

P2 Buildings and structures ~
- provide adequate daylight and
ventilation to habitable rooms; and
- allow adequate daylight and
ventilation to habitable rooms on
adjoining tots.

 

A2 (a) The side and rear boundary clearance
for a part of a building structure is -

(i} where the height of that part is 4.5
m or less — 1.5m;
(ii) where the height of that part is
greater thah 4:5m but not more
- than7.5m — 2m

(iii) where the height is greater than
’ 7.59 - 2m plus 0.5m for every 3m or

part exceeding 7.5m

The proposal compiles with (il) and (ill) above.

 

ROOF PITCH -

The proposed roof pitch iss degrées minimum.
SITE COVER

The proposed site cover is 40 %.

COASTAL PROTECTION PRECINCT

The site is located within the Coastal Protection Precinct, and the proposal is in partial accordance
with the requirements of Table 13.17 of the Noosa Plan, as per the following. Concession is sought

where indicated :

 

SPECIFIC OUTCOMES

PROBA BLE SOLUTIONS

 

 

Coastal Protection Precinct and Erosion Prone
Areas-Eastern Beaches Locality

017 The siting and design of development and
materials used within the Coastal Protection
Precinct.as identified on the Natural Resources
Overlay Maps, do not cause any significant
adverse impacts on the coastal resources of the
location nor interrupt the natural cycles of
erosion and accretion of foreshore areas and
beaches :

AND

 

$17.1 Buildings and ofher structures including
swimming pools, retaining walls and
landscaped teraces,,but excluding
cantitevered deck that are unclovered and
unenclosed-
a) donot extend seaward of the coastal
- building line: or
b) where a coastal 5uilding fine does not
exist on properties fronting the
beachfront or reserve adjoining the
beachfront-are setback a minimum of
&m from the seaward boundary of the
site: .
The proposed rear ( beachside ) house wall is
set back ém from the seaward boundary.
AND

 

 

 

Used in these records

About this file

File size
1.7 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0521 - MCU - Detached House - Bud Brannigan Architect [As Published].pdf · 1.7 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.