Council archive · source document
07/0521 - MCU - Detached House - Bud Brannigan Architect [As Published] · 132007.521
Side Boundary Clearance
Northem and southem side, and rear { eastern } boundary clearances are compliant with the
Queensland Development Code Part 12 - Design and Siting Standard :
PERFORMANCE CRITERIA
ACCEPTABLE SOLUTION
P2 Buildings and structures ~
- provide adequate daylight and
ventilation to habitable rooms; and
- allow adequate daylight and
ventilation to habitable rooms on
adjoining tots.
A2 (a) The side and rear boundary clearance
for a part of a building structure is -
(i} where the height of that part is 4.5
m or less — 1.5m;
(ii) where the height of that part is
greater thah 4:5m but not more
- than7.5m — 2m
(iii) where the height is greater than
’ 7.59 - 2m plus 0.5m for every 3m or
part exceeding 7.5m
The proposal compiles with (il) and (ill) above.
ROOF PITCH -
The proposed roof pitch iss degrées minimum.
SITE COVER
The proposed site cover is 40 %.
COASTAL PROTECTION PRECINCT
The site is located within the Coastal Protection Precinct, and the proposal is in partial accordance
with the requirements of Table 13.17 of the Noosa Plan, as per the following. Concession is sought
where indicated :
SPECIFIC OUTCOMES
PROBA BLE SOLUTIONS
Coastal Protection Precinct and Erosion Prone
Areas-Eastern Beaches Locality
017 The siting and design of development and
materials used within the Coastal Protection
Precinct.as identified on the Natural Resources
Overlay Maps, do not cause any significant
adverse impacts on the coastal resources of the
location nor interrupt the natural cycles of
erosion and accretion of foreshore areas and
beaches :
AND
$17.1 Buildings and ofher structures including
swimming pools, retaining walls and
landscaped teraces,,but excluding
cantitevered deck that are unclovered and
unenclosed-
a) donot extend seaward of the coastal
- building line: or
b) where a coastal 5uilding fine does not
exist on properties fronting the
beachfront or reserve adjoining the
beachfront-are setback a minimum of
&m from the seaward boundary of the
site: .
The proposed rear ( beachside ) house wall is
set back ém from the seaward boundary.
AND
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0521 - MCU - Detached House - Bud Brannigan Architect [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.7 MB (small file)
- File type
No other editions are linked here.