Council archive · source document
Delegated Report - Code - Planning MCU22 0052 [As Published] · MCU22/0052
a. Notifying all prospective guests on all advertising devices (i.e., websites, flyers,
brochures, etc.) that the site may be inaccessible during rain and fire events;
b. A process for management to advise booked guests for the potential for the site to be
inaccessible due to predicted weather events; and
c. On-site controls and processes for guests currently on-site during flooding and fire
events.
Water Supply
20. The development must be provided with a potable water supply connected to each cabin.
The storage capacity of the potable water supply must be a minimum of 5000 litres per
guest. The storage capacity of the potable water supply must be a minimum of 4000 litres
per guest bedroom/unit/cabin.
Wastewater Treatment and Disposal
21. The development must be provided with an on-site wastewater treatment and effluent
disposal system having a capacity sufficient for the use*.
*(Refer to Advisory Note)
Site Access and Driveways
22. An access driveway must be provided from Eastern Branch Road to all parking and
manoeuvring areas of the development. The access driveway must be constructed using
an all-purpose weather material. The works must be undertaken in accordance with an
Operational Works approval and must be generally in accordance with BAX Engineering’s
Roadworks Layout Plan Sheet 2 of 2 (dwg No. 304-001-302, Rev. B).
23. The property owner is wholly responsible for the ongoing maintenance of the proposed
gravel driveway and gravel walking track. The property owner must ensure that the gravel
driveway and gravel walking track are returned to their post-construction conditions after
inclement weather events that may have been damaged due to flooding or rainfall.
Car Parking
24. A minimum of 3 car parking spaces must be provided and marked on the site and made
available and accessible at all times while the use is open for business. The works must be
undertaken in accordance with an Operational Works approval, be generally in accordance
with BAX Engineering’s Overall Roadworks Layout Plan (dwg No. 304-001-300, Rev. B)
and must have dimensions, crossfalls and gradients in accordance with Australian
Standard AS2890: Parking Facilities.
25. All car parking areas and access driveways must be maintained exclusively for vehicle
parking and manoeuvring and kept in a tidy and safe condition at all times.
Stormwater Drainage
26. Stormwater runoff from the development must be disposed of on-site without causing scour
or damage to the subject site or any adjoining property.
Easements
27. Unless otherwise agreed in writing by the relevant service provider, any public or third party
infrastructure located on the subject site must be placed within an easement registered
against the title of the property.
28. All easements must be designed in accordance with the planning scheme and granted at
no cost to the Grantee. Where the Grantee is Council or a service authority, the easement
documentation must be in accordance with the Grantee’s standard easement terms. Draft
easement documentation must be submitted to Council for endorsement.
29. All works must be kept clear of any existing or proposed easements on the subject land,
unless agreed otherwise in writing by the Grantee.
Page 15 of 18
Document Set ID: 22700275
Version: 4, Version Date: 14/12/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Report - Code - Planning MCU22 0052 [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.