Part B - Attachments A to D

Attached to the e-mail Other Change Application – 132002.220285.5.

of 131

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

 Specific Outcome                                        Probable Solution                                                            Response
                                                                   d.    vehicular kerb and footpath crossings;
                                                                   e.    a constructed bikeway;
                                                                   f.    a constructed footpath;
                                                                   g.    a constructed carriageway;
                                                                   h.    required alterations to public utility mains, services or
                                                                         installations;
                                                                   i.    construction of any required alterations to public utility
                                                                         mains, services or installations;
                                                                   j.    stormwater drainage works; and
                                                                   k.    installation of electrical conduits; AND
                                                        S13.2      Road and drainage design and construction is in accordance
                                                                   with Sections 3 and 4 of PSP5 Engineering Design
                                                                   Standards – Roads, Drainage and Earthworks.
 14.148 Road and rail corridors

 O14     Noise sensitive uses including residential     S14.1      Noise sensitive uses including residential uses are                R14 Not Applicable
         uses are not subjected to high traffic noise              separated by a minimum of—
         levels from the major road network or rail                                                                                   The proposed development is located in the existing shopping
                                                                   a.    40m from the property boundary of roads within the           centre site in the car parking area, distanced from the road
         corridors.                                                      major road network; and                                      network.
                                                                   b.    80m from the property boundary of rail corridors;
                                                                   OR
                                                        S14.2      Development in the vicinity of road corridors meets the
                                                                   following external design criteria for roads in the major road
                                                                   network—
                                                                   a.    54dB(A)L10 (18hours) based on predicted traffic
                                                                         volumes ten years hence;
                                                                   AND
                                                        S14.3      Development in the vicinity of rail corridors meets the
                                                                   following external design level noise criteria—
                                                                   a.    65dB(a), assessed as the 24hour average equivalent
                                                                         continuous A- weighted sound pressure level; and
                                                                   b.    87dB(A), assessed as a single event maximum sound
                                                                         pressure level.
 14.149 Staged development

 O15     Staged development is planned, designed                   No solution provided.                                              R15 Not Applicable
         and constructed to ensure that—
                                                                                                                                      The development is not proposed to be staged.
         a.   each stage of the development can
              be constructed without interruption to
              services and utilities provided to the
              previous stages;




December 2017                                                   Cardno                                                                  8
Log in to download the original file

Part B - Attachments A to D.PDF · 5.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.