1909-13367 SRA RA6-N Response with conditions
Attached to the e-mail SARA Referral agency response – with conditions - MCU19/0114 & RAL19/0027.
1909-13367 SRA
No. Conditions Condition timing
(d) The road access works must be designed and constructed in
accordance with the Department of Transport and Main
Roads' Road Planning and Design Manual.
9. The emergency access is for use by emergency vehicles only as At all times
defined by Transport Operations (Road Use Management – Road
Rules) Regulation 2009 and must be gated and remain locked at
all other times.
10. (a) All redundant existing vehicular property access located Prior to the
between the proposed development and Cooroy Connection commencement of
Road must be permanently closed and removed. use
(b) The verge, including, but not limited to, local government
footpath, between the pavement edge and the property
boundary must be reinstated in accordance with the
Department of Transport and Main Roads' Road Planning and
Design Manual, standard drawings and specifications at no
cost to the Department of Transport and Main Roads'.
Managing noise impacts
11. (a) Noise attenuation measures to achieve the following noise (a) - (c) Prior to the
criteria must be provided: commencement of
(i) A noise barrier to meet the following external noise use and to be
criteria for the state-controlled road: maintained at all
For all facades of accommodation activities: times
≤60 dB(A) L10 (18 hour) façade corrected
(measured L90 (8 hour) free field between 10pm
and 6am ≤40 dB(A)).
≤63 dB(A) L10 (18 hour) façade corrected
(measured L90 (8 hour) free field between 10pm
and 6am >40 dB(A)).
For all outdoor spaces for passive recreation (private,
communal and public):
≤57 dB(A) L10 (18 hour) free field (measured L90
(18 hour) free field between 6am and 12 midnight
≤45 dB(A)).
≤60 dB(A) L10 (18 hour) free field (measured L90
(18 hour) free field between 6am and 12 midnight
>45 dB(A)).
(b) The noise barrier required in part (a) of this condition, must be
designed and constructed in accordance with:
Department of Transport and Main Roads' Road
Traffic Noise Management Code of Practice Chapter
7 integrated noise barrier design, Specifications
MRS15 and MRTS15; and
Standard Drawings Road Manual, Part 13.
(c) RPEQ certification with supporting documentation, including a
revised Acoustic Report, must be provided to the North Coast
District ([email protected]), within the
Department of Transport and Main Roads, confirming that the
Department of State Development, Manufacturing, Infrastructure and Planning Page 7 of 15