PLANNING & ENVIRONMENT COMMITTEE MEETING AGENDA                                   12 JUNE 2018


    28.   Buildings floor levels and bulk earthworks finish levels must take into consideration
          any building Minimum Floor Level required by the planning scheme at the time of
          construction.
    29.   Earthworks carried out on site must not adversely affect the drainage conditions on
          any other properties or existing roads, and/or the patterns and severity of flooding in
          the area particularly on downstream properties. Filling works required on site shall not
          cause additional ponding of water on any adjoining lands or the blockage of, or
          interference with, any natural watercourses. Detailed site surveys indicating natural
          surface levels and contours of any potentially affected properties must be provided
          with any application for a Development Permit for Operational Works for earthworks
          and/or stormwater drainage works. This may require the design and construction of
          drainage pipes and/or an overland flow-path within the development site to cater for
          drainage from the adjoining sites for a 1% AEP design storm.
          Erosion and Sediment Control
    30.   Any person acting on this permit shall prevent erosion and sediment export from
          leaving the site. Site control measures such as silt fencing, controlled gravel access
          to the site and controlled disposal of waste, will be necessary.
          In this regard plans detailing the methods of controlling erosion and sediment are
          required to be submitted to the Council for approval prior to obtaining a Development
          Permit for Operational Works.
          Power Supply
    31.   An underground electricity service shall be provided to the site if not already
          provided. In this regard, an approved ENERGEX Electrical Design Consultant shall
          work in conjunction with Council’s Manager - Works Support to prepare detailed
          designs of the electrical proposal.
          The detailed designs shall then be submitted to ENERGEX for approval and a copy
          of their approval submitted to Council with the application for Operational Works.
          Amalgamation of land
    32.   Prior to commencement of use, Lot 101 SP287641 must be amalgamated with Lot
          102 SP287641 and evidence (title and survey plan) provided to Council.
          Stormwater Quality and Drainage
    33.   A stormwater quality treatment system must be provided for the development to
          achieve an 80% reduction in Total Suspended Solids, 60% reduction in Total
          Phosphorous and 45% reduction in Total Nitrogen. A bio retention system with active
          filter media area of 75m2, depth of 40mm and extended detention depth of 200mmm
          is endorsed to achieve compliance with this condition.
    34.   The stormwater quality treatment system works must be undertaken and maintained
          in accordance with an Operational Works approval and the approved Stormwater
          Management Plan by Calibre Consulting dated February 2017 Doc Number 16-
          001014-02C.
    35.   The application for operational works for stormwater must include the following
          information in relation to any bio-retention system:
          a.    Survey information that demonstrates a free draining outlet from the sub-soil
                drainage system; and
          b.    Design Check Summary consistent with Section 3.1 of the approved
                Stormwater Management Plan by Calibre Consulting dated February 2017 Doc
                Number 16-001014-02C.



                                                                                   Page 43 of 97
Log in to download the original file

2018-06-12 Planning & Environment Committee Agenda(PDF, 11MB).pdf · 11.4 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.