App C - Slope Stability - 14-16 Duke St · 132008.299.02
4.3 Footings No design loadings were available at the time of reporting. Footings for the proposed buildings and any ancillary structures (e.g. retaining walls etc.) must penetrate through any fill materials and unsuitable natural soils (i.e. very loose to loose sands) to found at least 0.5 m into medium dense (or denser) sands. Based on our experience with similar sites in the area, the depth to medium dense (or denser) sands may be up to about 2 m BGL (existing). A geotechnical investigation is recommended to confirm the preliminary advice provided below. Piled footings may be required unless excavations expose medium dense sands at or near foundation subgrade level (e.g. in deeper excavation areas). Piles so founded may be designed using an allowable end bearing pressure (ABP) of 300 kPa. High-level footings may be possible in areas if medium dense (or denser) sands are exposed at or near the subgrade. This would be subject to an assessment by a suitably qualified and experienced geotechnical RPEQ during construction. High-level footings, so founded, could be designed using an ABP of 100 kPa. Footing design should also account for potential soil reactivity. Given the sandy soil profile and depths of footings required, steel screw piles are an appropriate footing type for the proposed development generally. However, in areas of cut exposing medium dense (or denser) sands at the subgrade level high-level footings may be adopted. It should be noted that excavations for concrete strip footings (or similar) may loosen the base. Therefore, the use of a vibrating plate would be required to densify any high-level footing bases prior to the placement of reinforcing steel. Due to the likely presence of loose sands, together with the close proximity to surrounding infrastructure, open bored piers or driven piles are not considered to be appropriate for this site. Steel reinforced concrete bored piles could be feasible; however, the use of sacrificial liners (e.g. ‘formatube’) would be required to prevent the caving of upper loose sands. The advice of a specialist piling contractor must be sought regarding feasibility, design and installation of the piling system for this site, including an assessment of potential vibration effects on nearby structures, and monitoring requirements. If steel screw piles are adopted, it will be important to ensure close supervision of installation, as piling may not encounter sufficient drilling resistance (from torque measurement) in sands at the suggested founding depth and piles could extend to much greater depth than necessary. It is therefore recommended that site-specific static load testing be conducted from screw piles, if adopted, at a minimum. Where tension or compression capacity developed in the footings is critical for the future structure (e.g. resistance to uplift forces from high winds), then cyclic load tests (including measurement of deflections under tension and compression cycles) should also be undertaken prior to construction. Kentledge for static testing, or simulated cyclic loads, should prove the piles to a minimum of two times the expected working load within tolerable deflections. All footings should found such that they are not adversely affected by (or affect) any adjacent excavations, trenches or retaining walls that are not designed to support building loads. Footings should found at least below a plane extending 1 m horizontally from the base of trenches/excavations/retaining walls, then rising up at 1V:1H, as illustrated in Text Figure 9 overleaf. Where footings are located within a horizontal distance of 1.5H (H being the batter height) of any cut or fill batter crest, these footings must be founded at a depth level with the toe of the batter. 21 October 2025 25317-001-Rev0 11 of 13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
App C - Slope Stability - 14-16 Duke St.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.