4.3      Footings
No design loadings were available at the time of reporting. Footings for the proposed buildings and any
ancillary structures (e.g. retaining walls etc.) must penetrate through any fill materials and unsuitable
natural soils (i.e. very loose to loose sands) to found at least 0.5 m into medium dense (or denser) sands.
Based on our experience with similar sites in the area, the depth to medium dense (or denser) sands may
be up to about 2 m BGL (existing). A geotechnical investigation is recommended to confirm the
preliminary advice provided below. Piled footings may be required unless excavations expose medium
dense sands at or near foundation subgrade level (e.g. in deeper excavation areas).
Piles so founded may be designed using an allowable end bearing pressure (ABP) of 300 kPa. High-level
footings may be possible in areas if medium dense (or denser) sands are exposed at or near the
subgrade. This would be subject to an assessment by a suitably qualified and experienced geotechnical
RPEQ during construction. High-level footings, so founded, could be designed using an ABP of 100 kPa.
Footing design should also account for potential soil reactivity.
Given the sandy soil profile and depths of footings required, steel screw piles are an appropriate footing
type for the proposed development generally. However, in areas of cut exposing medium dense (or
denser) sands at the subgrade level high-level footings may be adopted. It should be noted that
excavations for concrete strip footings (or similar) may loosen the base. Therefore, the use of a vibrating
plate would be required to densify any high-level footing bases prior to the placement of reinforcing
steel.
Due to the likely presence of loose sands, together with the close proximity to surrounding infrastructure,
open bored piers or driven piles are not considered to be appropriate for this site. Steel reinforced
concrete bored piles could be feasible; however, the use of sacrificial liners (e.g. ‘formatube’) would be
required to prevent the caving of upper loose sands.
The advice of a specialist piling contractor must be sought regarding feasibility, design and installation of
the piling system for this site, including an assessment of potential vibration effects on nearby structures,
and monitoring requirements.
If steel screw piles are adopted, it will be important to ensure close supervision of installation, as piling
may not encounter sufficient drilling resistance (from torque measurement) in sands at the suggested
founding depth and piles could extend to much greater depth than necessary.
It is therefore recommended that site-specific static load testing be conducted from screw piles, if
adopted, at a minimum. Where tension or compression capacity developed in the footings is critical for
the future structure (e.g. resistance to uplift forces from high winds), then cyclic load tests (including
measurement of deflections under tension and compression cycles) should also be undertaken prior to
construction. Kentledge for static testing, or simulated cyclic loads, should prove the piles to a minimum
of two times the expected working load within tolerable deflections.
All footings should found such that they are not adversely affected by (or affect) any adjacent
excavations, trenches or retaining walls that are not designed to support building loads. Footings should
found at least below a plane extending 1 m horizontally from the base of trenches/excavations/retaining
walls, then rising up at 1V:1H, as illustrated in Text Figure 9 overleaf.
Where footings are located within a horizontal distance of 1.5H (H being the batter height) of any cut or
fill batter crest, these footings must be founded at a depth level with the toe of the batter.




21 October 2025
25317-001-Rev0                                                                                        11 of 13

Used in these records

About this file

File size
4.2 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

App C - Slope Stability - 14-16 Duke St.pdf · 4.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.