Log in to see the plans as drawnBrown Rooster Pty Ltd - Duplex - 27 Grant Street, Noosa Heads dennishillarchitect [OCR of page images] dennishillarchitect NY O 5 O x 5D Nn 3 O Z io © a Cc o O —~ N x< ae Oo > a Brown Rooster Pty Ltd
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of pages 2 to 13 (of 16)
Page 2
COPYRIGHT: Drawings remain the Copyright of the Architect: Dennis Hill Architect LICENSED TRADESPERSONS: All services to be installed by licensed tradespersons in accordance with • no exposed gables to joinery unless noted otherwise
ALL WORKS shall be carried out in accordance with the Building Code of Australia, Australian Standards, local authority and with current manufacturers specifications.
Local Council requirements, QDC guidelines and all other relevant by laws and authorities. In particular ROOF DRAINAGE: All downpipes to be located as noted on the drawings and sizes as scheduled. • all tops and carcasses to be flush unless noted otherwise
refer Australian standards: Allow to connect to in-ground storm water drains with 90mmDIA UPVC at 1:100 minimum grade.
. site preparation A.S. 3798 Allow for I.O.'s at each change fo direction and at 6000mm centres • all edges to be square unless noted otherwise
. termite protection BCA and A.S. 3660.1 SITE DISCHARGE: All stormwater and sanitary plumbing to be connected to existing council system
. artificial lighting & ventilation BCA parts 3.8.4/3.8.5 and A.S. 1680 in accordance with the requirements of the relevant local authority. • all joinery units to have carcass constructed of 16mm or 25mm thick
. fire safety BCA part 3.7 WATER LINES: All hot water lines shall be fully insulated. All domestic hot water to basins, showers pre-finished board unless noted otherwise
. smoke alarms BCA part 3.7.2 and A.S. 3786 and baths to have maximum temperature of 50°C. Allow to supply and install tempering valves
. glazing BCA part 3.6 and A.S. 1288 and A.S. 2047 where required, as nominated in the BCA and relevant standards. • all laminated joinery to have matching abs edging unless noted otherwise
APPROVAL: No building work shall be undertaken prior to Building Approval by a registered Certifier. STAIR AND BALUSTRADES: All stair and balustrades shall comply with part 3.9 of the BCA. Steps to be
CONSULTANTS : Drawings shall be read in conjunction with engineers drawings and computations. All provided where fall from dwelling exceeds 190mm. • all joinery units to have 100mm high skirting unless noted otherwise
structure to Engineers design. All drawings to be co-ordinated with consultant documentation prior to ALL PRODUCTS: To be installed to manufacturers requirements and to be in accordance with
general construction notes
construction. manufacturers requirements for suitable exposure levels. • all timber veneer joinery to have matching solid timber edging
DIMENSIONS: Do not scale off drawings - use figured dimensions only. Contractor shall verify all PROPRIETARY ITEMS: Identification of a proprietary item does not necessarily imply exclusive
general joinery notes
dimensions on site prior to construction. Any discrepancies or errors shall be referred to architect and preference for the item so identified, but indicates the necessary properties of the item. If • all drawers to have high sides
client prior to installation / manufacture of any works. Confirm levels & RL's on site prior to alternatives are proposed, submit proposed alternatives and include samples, available technical
commencement of work. information, reasons for proposed substitutions and cost. • all adjustable shelves shall be supported on brass ferrules and bushes
SETOUT: Contractor to confirm exact siting and orientation prior to construction setout. All building setout TILES: Expansion joints, walls: 5mm. Floors: 8mm. Fill both with silicone rubber. Grout for wall: Epoxy - supports to be at 50mm centres
and confirmation of setbacks and height to be carried out by a Licensed Surveyor. No footing, or wall to based mildew resistant. Grout for floors: prepared grout to be acid resistant. all wall tiles to have fc
encroach the title boundary. substrate. • all hinged doors to be hung on fully concealed all metal type wide
TERMITE PROTECTION: Termite protection by means of termimesh s.s. mesh physical barrier in INTERNAL PAINTING: Unless noted otherwise paint system to be Dulux approved 3 coat system - low angle hinges
accordance with A.S. 3660.1/2000 and installed in strict accordance with current manufacturers sheen finish. Colours to be supplied by Architect during contract and applied as per Dulux's
specifications. recommendations and guidelines. • all cover plates, gpo's and data outlets etc to be white if located on
STRUCTURAL STEEL: Unless noted otherwise all exposed structural steel, anchor bolts and other JOINERY ITEMS SHALL INCLUDE: Manufactured casework items, including: kitchen cabinets and white wall or corian, otherwise to be stainless steel finish
attachments shall be hot dip galvanised. A cold gal painted finish shall be applied to any field welding cupboards; bathroom cabinets; robes.
to existing or new steelwork. All steel work cast in concrete footings or slab shall have a bitumen finish SANITARY COMPARTMENTS: Provide removable hinges to doors of sanitary compartments to • builder to provide adequate noggings to support all bathroom
applied to full extent of cast in concrete steel. Check all dimensions on site prior to fabrication of comply with BCA 3.8.3.3 and be readily removable from outside unless there is a clear space of at accessories and suspended joinery
steelwork. least 1200mm b/w closet pan within the sanitary compartment and the nearest part of the
RETAINING WALLS: All retaining walls to structural engineers details. Provide rubble backfill and agg doorway. • all dimensions to be checked on site prior to manufacture of joinery
drainage to all retaining walls. Builder to provide tanking where required. APPLIANCES & EQUIPMENT: Builder to co-ordinate all appliance and equipment locations on site
SLAB & FOOTINGS: All slabs and footings to structural engineers details. A polyethylene moisture barrier and with joiner. installation and final connection by the contractor. • finish to underside of overhead cupboards to match joinery fronts
shall be lapped 200mm and fully taped under any habitable concrete slab and shall extend 100mm WEATHERSTRIPS: All external doors to contain weather stripping (type to be confirmed by Architect
onto the perimeter footing. prior to manufacture) • all joinery drawings to be read in conjunction with architectural
ARTICULATION JOINTS: Provide articulation joints to comply with "Cement and Concrete Association DOCUMENTATION: The contractor shall carry out works in accordance with the signed drawings and drawings and finishes & fixtures schedule - all discrepancies to be
Construction Note TN9". schedules and anything reasonable inferred, and with the Conditions of Contract, and in referred to the builder and architect for resolution
EROSION CONTROLS: All building works to comply with local authorities Erosion and sediment control accordance with the directions and to the satisfaction of the Architect, whose interpretation of the
standards. contract documents shall be final. The drawings and specifications/schedules shall be considered • builder to co-ordinate all appliance and equipment locations on site
WATERPROOFING: All wet areas and walls to be waterproofed in accordance with the BCA 3.8 & AS complementary, and any work and/or materials absent from one but present or implied in the and with joiner. Installation and final connection by the contractor.
3740. Builder to provide certificate of installation and compliance. other shall be furnished as if they were present in both. Joiner to confirm all appliance and equipment tolerances and
CONCEALMENT OF SERVICES: All services shall be concealed in walls or ducts. Where services are FINAL CERTIFICATE: At completion of work - Builder to obtain. requirements in joinery prior to fabrication
exposed they must be confirmed by the Designer on site prior to installation unless noted otherwise.
bal01 timber framed glass balustrade pol01 polished concrete FSL X.XXX spot level
27 Grant Street total site 546 m² totals
Noosa Heads Qld 4567 top of wall / fence level
bal02 timber balustrade tim01 hardwood timber floor TOW X.XXX
total site 546 m²
Lower level GFA total site cover 218.3 m² SSL X.XXX structural slab level
fc01 scyon axon fibre cement cladding tim02 hardwood timber decking
Council - Noosa Council proposed internal 123.1 m² site cover ratio 40% = 218.4 m²
Zoning - Medium Density Residential pb01 plasterboard lining FFL X.XXX finished floor level
Neighbourhood Plan -
Noosa Plan 2020 ground level GFA L1 indicates building level
vj01 vj sheet lining
proposed internal 95.2 m² w01 indicates window number
garage (not incl.) 83.6 m²
project details
Site Area: 545.38 m²
mrf01 metal flashing - colorbond finish
Lot: 6 SP179879 L1 indicates building level
floor areas
Building Classification: 1a d01 indicates door number
finishes
legend
mrs01 metal roof sheeting - colorbond finish
Storeys: 2 garage-top terrace
Climate Zone: 2 not included as roof/shelter does pnt01
pnt01 epoxy paint finish finish/material type as scheduled
Wind Category N3 not extend beyond 3m from an
20
exterior wall
ren01 rough sand and cement render slab setdown
total GFA (excl. garage) hc
tbs01 timber batten screen hose cock
= 218.3 m²
dp
ms01 metal screen down pipe
dr01
til01 crazy paving drainage pit
til02 ceramic tile
con01 large format concrete paver
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty COVER NOTES DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.001
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:04:54 PM
Page 3
2 x 45L Acronichia imperforata
Street Trees
GR
AN
T
ST
RE
ET
Drawing Schedule
Sheet No. Sheet Name Revision Current Revision Date
BA.090 STRUCTURAL GENERAL NOTES D 10/12/2020
Landscaping Area = 218m2 (40%) with 60% soft landscaping
A mix of 25L coastal species (as per the highlited species below) with 1m centres in areas marked above
All plants are to be planted, staked and maintained in accordance with PSP2.
INDICATES BUILDING
FOOTPRINT
Plan
SITE PLAN - Proposed 1 : 200
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty SITE PLAN DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 As indicated
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.01
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:00 PM
Page 4
ppers
one ste
paling
fence large st
1500 4.5m (h
)
tback to
1.5m se
2000
yard 7m (h )
paling fence
nom. 1000mm
tback to
2.0m se
bed 2 bed 3
robe
4500
setback to rear boundary ens
(h) retaining
robe robe
robe
bthrm
GFA
wall
undercroft /
SLIDING DOOR
services
ls deck master
deck
suite ldry
rendered blockwork fence
-1m high (under -stair)
N WALL (60 /60/60)
FIRE SEPARATIO
ldry
nom. 1000mm(
Site Cover
(under-stair) dercroft /
un
servic es
SLIDING DOOR
1
master
BA.071
timber suite robe
robe
'retreat'
h) retaining wa
deck bthrm
robe
ens bed 3
bed 2
ll
1
robe
BA.070
paling fence
2.0m setback to 7m (h)
yard 1.5m setback to 4.5m (h)
2000
1500
large stone steppers
paling fence
Plan
Lower Level 1 : 100
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty FLOOR PLAN - DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd LOWER LVL
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.02
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:00 PM
Page 5
BINS
GRANT STREET
ppers
Letterbox
one ste
line o f so
ffit over
timber large st
ppers
one ste deck/p
ath
large st
ve r
w ning o
footpath
line of a
grated
DN
2.0°
1500
tren
2000
ch drain
cab.
)
4.5m (h
tback to
entry
storage
1.5m se
7m (h )
tback to
2.0m se BENCHTOP
garage
BULKHEAD
SL
SL
STACKING SL
balc.
4500 GFA pdr
IDER
setback to rear boundary
6000
4000
5000
dining kitchen living driveway
DN N WALL (60 /60/60)
FIRE SEPARATIO
SL
SL
Site Cover
SL
SL
grated trench drain
SL 6000
SL
SL
SL
SL DN setback to front boundary
SL
SL
SL
1
pdr
living
BA.071
kitchen
line of soffit over
garage
dining
STACKING SLIDE
BULKHEAD
storage
footpath
balc. SL
cab.
SL
R
Letterbox
entry
1
BA.070 BENCHTOP
DN timber
2.0°
large stone steppers
2.0m setback to 7m (h) deck/path
1.5m setback to 4.5m (h)
2000
line of awning over line of soffit over
BINS
1500
large stone steppers
1500
Plan
Ground Floor Plan 1 : 100
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty FLOOR PLAN - DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd GROUND LVL
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.03
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:12 PM
Page 6
footpath
ENING
Y SC RE
PR IVAC
bbq
pool pool
pump PRE CA
ST
ELL
POOL SH
rooftop
deck
OVER
LINE OF ROOF
N WALL (60 /60/60)
FIRE SEPARATIO
1
BA.071 OVER
LINE OF ROOF
rooftop 3
BA.080
deck
footpath
pool
pool PRECAST
pump POOL SHELL
bbq
1
BA.070
PRIVACY SCREENING
Plan
Upper Level 1 : 100
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty FLOOR PLAN - DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd UPPER LVL
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.04
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:14 PM
Page 7
Plan
ROOF DRAINAGE PLAN 1 : 100
TO
AW NING EAVES
GRO UND LVL
DP rooftop
deck
W-29 W-30
LINE OF BUILD
nt
Roof Catchme
= 148 sqm 1:100 FALL
FORMED ROOF
ING UNDER
STRUCTURE
/60)
N WALL (60/60
FIRE SEPARATIO
W-27 W-28
W-25 W-26
W-24
FORMED ROOF
W-22 W-23 STRUCTURE
W-20 W-21
DP W-19 1:100 FALL
1
BA.071
LINE OF BUILD
rooftop
deck
ING UNDER
W-18 W-17
1
ES TO
BA.070 AW NING EAV
GROUND LVL
DP
DRAINAGE
NOTES:
Based on assumed 5 minute rainfall intensity - • Effective roof catchment area (extension Downpipes are to be located where they will Downpipes are to service 12m maximum
All work to conform with Part MP 4.2 of the 189mm/h 20 years recurrence interval. only) 152 m² not create a hazard to building users nor gutter length & be within 1.2m from each
Queensland Development Code (QDC) • Roof catchment per downpipe 60m² impede window & door openings and the valley unless overflow is provided for (NCC
(Water Saving Targets). Gutters & downpipes shall be in accordance • Downpipes must not serve more than like. They are to be installed as close as Vol2 P3.5.2.5)
with AS/NZS3500.5 domestic & Part 3.5.2, Vol 2 12m of gutter length for each downpipe practicable to the supporting structure while
Roof stormwater is to discharge to local of the NCC. • Total rainfall intensity 148m² X 189mm/60 maintaining termite inspection clearances of
government requirements and approval. = 466.2L/min 25mm. Downpipes are to be protected from
Tank/s overflow and downpipes not All downpipes to be 90mm/100mm U-PVC. • Stormwater pipes - 100 dia. Laid at 1 in potential mechanical damage, be installed
connected to rainwater tank/s to discharge All gutters to be 150 Quad Gutters (8600mm² 100 minimum grade. no less than 100mm from electrical cables &
to interallotment drainage system/ to Cross section area). gas pipes & no less than 50mm from other
nominated discharge points via bubbler Falls to be in accordance with clause 3.5.2.4, services (AS3500.3.2 S4.11)
system/ to discharge to street channel system. Vol 2 of the NCC.
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty ROOF DRAINAGE DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd PLAN
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.05
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:15 PM
Page 8
D-35
Mark Width Height Type Comments
door
custom garage tilt
D-36
D-01 2400 2400 Signature Sliding Door (100mm)
D-11 custom garage
tilt door
D-12 D-02 2400 2400 Signature Sliding Door (100mm)
W-01
D-03 2470 2100 2 Panel Robe Door - VJ profile
W-03
D-04 2470 2100 2 Panel Robe Door - VJ profile
D-19 D-05 2470 2100 2 Panel Robe Door - VJ profile
D-20
D-06 2470 2100 2 Panel Robe Door - VJ profile
D-08 D-07 1935 2100 2 Panel Robe Door - VJ profile
D-07 D-09 D-08 2852 2100 2 Panel Robe Door - VJ profile
W-02 D-10 D-09 2961 2100 2 Panel Robe Door - VJ profile
W-04
D-31
D-32
D-10 1935 2100 2 Panel Robe Door - VJ profile
D-17 D-11 1935 2100 2 Panel Robe Door - VJ profile
D-33
D-34
D-18 D-12 1935 2100 2 Panel Robe Door - VJ profile
W-05 D-29 D-13 620 2040 VJ profile double swing door
D-27
W-06 D-14 620 2040 VJ profile double swing door
D-15 D-30 D-15 820 2400 Cavity pocket slider - VJ profile door
D-28
D-16 D-16 820 2400 Cavity pocket slider - VJ profile door
D-17 820 2040 VJ profile swing door
W-07 D-18 820 2040 VJ profile swing door
D-13
W-08
D-14
D-25 D-19 820 2040 VJ profile swing door
D-20 820 2040 VJ profile swing door
D-26 D-25 1000 2400 Custom cedar glass swing door - single lite
W-15
D-03 D-04 D-26 1000 2400 Custom cedar glass swing door - single lite
D-01
D-05 D-06 D-27 820 2040 VJ profile swing door
W-16
D-02
D-28 820 2040 VJ profile swing door
D-29 820 2400 Cavity pocket slider - VJ profile door
W-09 D-30 820 2400 Cavity pocket slider - VJ profile door
custom glazing (NOT INCL. IN SCHEDULE) W-10 D-31 1570 2100 2 Panel Robe Door - VJ profile
Plan D-32
D-33
1608
1465
2100
2100
2 Panel Robe Door - VJ profile
2 Panel Robe Door - VJ profile
5
LOWER LEVEL - DOOR & 1 : 125 D-34 1676 2100 2 Panel Robe Door - VJ profile
BA.10
WINDOW PLAN
4300 4300
Head
Number Height Width Height Type Comments
hydraulic awning
2400
D-23
windows W-01 1500 1810 2400 Aluminium framed glass slider XO
D-24
(NOT INCL. IN SCHEDULE)
1000
W-02 1500 1810 2400 Aluminium framed glass slider XO
custom casements
fixed fixed fixed fixed fixed Ground Floor Level
fixed fixed fixed
(NOT INCL. IN SCHEDULE)
W-03 1500 1810 2400 Aluminium framed glass slider XO
RL 17.464 m W-13 W-04 1500 1810 2400 Aluminium framed glass slider XO
custom casements
WINDOWS - W-11 / W-12 Aluminium framed glazing suites (safety glass)
W-14
W-05 2400 600 2400 Aluminium framed glass louvres
4 Section W-06
W-07
2400
600
600
1600
2400
2400
Aluminium framed glass louvres
Aluminium framed 2-bay glass louvres (frosted)
BA.10 Awning Glazing Detail 1 : 125 W-08 600 1600 2400 Aluminium framed 2-bay glass louvres (frosted)
W-09 2400 900 2400 Aluminium framed glass louvres
4400
W-11 W-10 2400 900 2400 Aluminium framed glass louvres
4 W-12 W-17 1420 567 Velux Skylight
BA.10
CASEMENTS - W-13 & W-14 MIRROR-TYPICAL
Plan custom glazing (NOT INCL. IN SCHEDULE) W-18 1420 567 Velux Skylight
1200
Aluminium framed casement suites 3 W-19 1420 567 Velux Skylight
with hinged angle privacy screens GROUND LEVEL - DOOR & 1 : 125 W-20 1420 567 Velux Skylight
BA.10
WINDOW PLAN W-21 1420 567 Velux Skylight
Ground Floor Level W-22 1420 567 Velux Skylight
RL 17.464 m 1800 1000 W-23 1420 567 Velux Skylight
W-24 1420 567 Velux Skylight
3 Section SINGLE FIXED PANEL -
W-15 & W-16 MIRROR-TYPICAL
W-25 1420 567 Velux Skylight
BA.10 1 : 125 W-26 1420 567 Velux Skylight
Solid Leaf - Casement Detail
2400
Aluminium framed - fixed single panel glazing suites W-27 1420 567 Velux Skylight
with timber batten privacy screens
W-28 1420 567 Velux Skylight
Ground Floor Level W-29 1420 567 Velux Skylight
RL 17.464 m W-30 1420 567 Velux Skylight
5 Section
BA.10 Battened Fixed Glazing Detail 1 : 125
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty DOOR & WINDOW DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 125
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd PLAN
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.10
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:15 PM
Page 9
6000 23210 4500
8m m
ax im
rear setback
um h
boundary
eigh
front setback
t
190 series blockwork with Concrete-look Timber Concrete-look
selected render finish render finish battens render finish
Rooftop Level
RL 23.484 m
boundary
Velux Skylights FC sheeting with Hardies Axon Fixed angle aluminium Metal roofing, fascias, barges and
cover-strips Cladding privacy blades gutters in Colorbond Basalt
2700
5500
Upper Level
RL 20.784 m
2600
Garage Level
RL 18.184 m
720
Ground Floor Level
RL 17.464 m
Aluminium batten balustrade
1 Elevation Timber
3000
battens
Elevation NW 1 : 100
Stone Lower Level
steppers RL 14.464 m
190 series blockwork with
selected render finish
Timber batten Concrete-look
privacy screens render finish
Concrete-look Concrete-look
render finish render finish
timber batten screen timber batten screen
suspended conc. planter suspended conc. planter
Upper Level
RL 20.784 m
Concrete-look
render finish
Aluminium batten Aluminium batten balustrade
balustrade
Garage Level
RL 18.184 m
Timber battens to tilt Concrete-look Selected finish to tilt Concrete-look
panel garage door render finish panel garage door render finish
2 Elevation
Elevation NE 1 : 100
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty ELEVATIONS DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.060
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:19 PM
Page 10
Concrete-look Timber Concrete-look 190 series blockwork with
60/60/60 fire render finish battens render finish selected render finish
separation wall
Rooftop Level
RL 23.484 m
Metal roofing, fascias, barges and Hinged aluminium Hardies Axon FC sheeting with Velux Skylights
gutters in Colorbond Basalt privacy blades Cladding cover-strips
Upper Level
RL 20.784 m
um height
6640
8m maxim
Garage Level
RL 18.184 m
Ground Floor Level
RL 17.464 m
Under-croft
Aluminium batten
balustrade
Timber
battens
Stone
Lower Level steppers
RL 14.464 m
Velux Skylights Concrete-look
render finish
Metal roofing, fascias, barges and
gutters in Colorbond Basalt
Rooftop Level
RL 23.484 m
2 Elevation
Elevation SE 1 : 100
FC sheeting with
cover-strips
Upper Level
RL 20.784 m
190 series blockwork with
selected render finish
Aluminium batten
balustrade
Garage Level
RL 18.184 m
Ground Floor Level
RL 17.464 m
Hardies Axon
Cladding
Lower Level
RL 14.464 m
Galv. steel posts to
engineers specification
1 Elevation
Elevation SW 1 : 100
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty ELEVATIONS DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.061
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:25 PM
Page 11
FIRE SEP WALL CONTINUES TO UNDERSIDE OF ROOF SHEET
Rooftop Level
RL 23.484 m
Raftered roof to engineers
specification rooftop Suspended slab to engineers
Precast Pool details
Upper Level
RL 20.784 m
kitchen garage
dining living
Garage Level
RL 18.184 m
Ground Floor Level
RL 17.464 m
Suspended timber framed Driveway slab and footings to
floors to engineers engineers details
specification
Corefilled blockwork columns
WIR ens bed 2 bed 3 to engineers specification
Lower Level
RL 14.464 m
Blockwork wall and retaining
Galv. steel posts to engineers details
and bracing to
engineers detail
Concrete slab and footings
to engineers details
UNITS 1 & 2 = MIRROR/TYPICAL
1 Section
BA.02 Section - A 1 : 100
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty BUILDING DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd SECTIONS
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.070
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:27 PM
Page 12
Rooftop Level
FIRE SEP WALL CONTINUES TO UNDERSIDE OF ROOF SHEET RL 23.484 m
Raftered roof to engineers
specification rooftop Suspended slab to engineers
details
Upper Level
RL 20.784 m
garage
dining living
Garage Level
RL 18.184 m
Ground Floor Level
RL 17.464 m
Suspended timber framed Driveway slab and footings to
floors to engineers engineers details
specification laundry undercroft
Lower Level
RL 14.464 m
Blockwork wall and retaining
Galv. steel posts and to engineers details
bracing to engineers detail
Concrete slab and footings
to engineers details
1 Section UNITS 1 & 2 = MIRROR/TYPICAL
BA.02 Section - B 1 : 100
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty BUILDING DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd SECTIONS
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.071
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:28 PM
Page 13
4
BA.080
190
2120
2500
POOL
1
BA.080
190
1000 190 2120 190
2500
Plan
PLAN VIEW - POOL DETAIL 1 : 50
Illustration
POOL DETAIL
1 4
BA.080 BA.080
solid wall stair glass stair precast
balustrade balustrade concrete pool
timber batten
privacy screen
precast pool shell
Blockwork wall shallow
landscape
1200
planter
pool
1400
pool
200
Upper Level Upper Level
RL 20.784 m RL 20.784 m
2500 shallow landscape garage under
planter
190 2120 190
4 Section 1 Section 2500
BA.080 POOL SECTION A 1 : 50 BA.080 POOL SECTION B 1 : 50
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty POOL DETAIL DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 50
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.080
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:29 PM
The text continues on page 14.