Council archive · source document
SUPERSEDED - Minor Change Existing Approval 132002 220460 4 [As Published] · 132002.220460.4
Environmental Health
40. The development must be undertaken and operated in a manner that causes no detrimental
effect upon the amenity of the neighbourhood by reason of the creation of excessive noise,
lighting, dust or odour nuisance or any other emissions in accordance with the nuisance
provisions of the Environmental Protection Regulation 1998. On the spot fines apply for such
offences.
41. Swimming pool or spa pumps are to be contained in an acoustically treated enclosure or
located in a manner which prevents a noise nuisance beyond the subject land in accordance
with the nuisance provisions of the Environmental Protection Regulation 1998. On the spot
fines apply for such offences.
42. All lift plant including motors, shall be situated within the building or suitably provided with
noise reduction measures and located as to prevent a noise nuisance beyond the subject
land in accordance with the nuisance provisions of the Environmental Protection Regulation
1998. On the spot fines apply for such offences.
43. Air conditioning units shall be located in a manner which prevents noise nuisance beyond
the subject land in accordance with the nuisance provisions of the Environmental Protection
Regulation 1998 and Council’s Local Law No. 12 - Control of Nuisances. On the spot fines
apply for such offences.
An occupier of premises where there is air-conditioning equipment must not use or allow the
use of the equipment -
43.1. before 7am or after 10pm on any day if it makes noise or causes noise to be made of
more than the higher of the following -
43.1.1. 40 dB(A)
43.1.2. 3 dB(A) above the background noise level
43.2. from 7am to 7pm on any day if it makes noise or causes noise to be made of more than
the lower of either of the following -
43.2.1. 50 dB(A)
43.2.2. 5 dB(A) above the background noise level
43.3. from 7pm to 10pm on any day if it makes noise or causes noise to be made of more
than 3 dB(A) above the background noise level.
44. Swimming/spa pool fencing, gates and wall openings within these areas to comply with
Australian Standard 1926 for pool safety. Display resuscitation chart at each pool, which are
free from Council’s Environmental Health Section.
Building
45. There is to be no uncontrolled discharge of water onto the slope.
46. Stripping of vegetation for construction purposes should be minimised. If vegetation is
destroyed it should be reinstated immediately after construction is completed.
47. Additional load due to fill, construction equipment or stockpiled materials should not be
located on the dune slope. Filling in the open space area is to be avoided.
48. The use of vibratory equipment of any kind is not permitted to be used, including vibrating
rollers, the use of vibrating installation techniques for sheet piling and other construction
vibrations caused by excavating, earthmoving or demolition machinery or other similar
construction techniques.
49. A condition survey is to be carried out of adjoining buildings, structures and services prior to
any construction works taking place on site. If distress already exists, a photographic survey
shall be undertaken, the distress measured and a plan to monitor changes to distress shall
be implemented. A copy of this report is to be submitted to Council within 5 business days of
survey and prior to construction work proceeding.
Page 6 of 9
Document Set ID: 20570273
Version: 4, Version Date: 01/05/2018
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Minor Change Existing Approval 132002 220460 4 [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 205 KB (small file)
- File type
No other editions are linked here.