Skip to the record
The only place to find full transcripts.

Original source · versioned page text

Attachment 2 - Sealed Final Judgment

Attached to the e-mail Pre-Request Response Application - MCU14/0008.03.

of 36

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (19.6 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

42. Construction works undertaken in the vicinity of Unitywater water supply or sewerage
      infrastructure must not adversely affect the integrity of the infrastructure. All costs
      associated with repair, replacement or alteration of infrastructure must be met by the
      applicant.
Additional Condition:
43. An acoustic barrier must be erected and maintained along the north-eastern boundary
         and eastern boundary of Lot 12 on SP-2©4^405r The barrier must meet the following
         design specifications: 20-7(0^
         (a) Be of a height of at least 1.8 metres above ground level
         (b) Be constructed of infill panels of either timber or plywood (of a stress grade 4 or
                greater and a minimum density of 12.5kg/m2). Timber slats 100mm x 25mm with
                a minimum overlap of 25mm would satisfy this requirement
         (c) Posts are to be structural timber and have minimum dimensions of 100mm x
                100mm
         (d) Cladding above ground level is to be treated to Hazard Level 3 or better
         (e) Timber in contact with the ground is to be treated to Hazard Level 4 or greater
         (f) All timber is to be CCA treated
         Evidence that the fence has been constructed in accordance with the required timber
         treatments must be provided to Council.

5 REFERRAL AGENCIES
The referral agencies applicable to this application are:

Referral       Referral Agency and             Referral         Response
Status         Address                         Trigger
Concurrenc     SARA at DSDIP Mike Ahern        Unexploded       The agency provided its
e              Government Building 12 First    ordnance         response on 20 March 2014
               Avenue MAROOCHYDORE                              (Reference No SDA-0214-
               QLD 4558                                         008010.). A copy of the
                                                                response is attached.

Advice         Energex Limited Town            Electricity      The agency provided its
               Planning GPO Box 1461           Infrastructure   response on 19 March 2014
               BRISBANE QLD 4001                                (Ref No HBD 3885110
                                                                317962)

6 ADVISORY NOTES
The following notes are included for guidance and information purposes only and do not form
part of the assessment manager conditions:
Development Compliance Inspection
43. Prior to the commencement of the use, please contact Council's Development Audit &
     Response Unit to arrange a Development Compliance Inspection.




   Page 9 of 36
Log in to download the original file

Attachment 2 - Sealed Final Judgment.pdf · 19.6 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.