FURTHER REPORT - Planning & Environment Committee 6 May 2025 MCU21/0110
PLANNING AND ENVIRONMENT COMMITTEE MEETING REPORT 6 MAY 2025
Tennis Court Operating Hours
29. Tennis courts must not be illuminated after 10.00p.m. nor before 7.30 a.m.
Structural Stability
30. All lighting support columns must be manufactured from galvanised steel.
31. The pole height shall not exceed 8 metres.
32. The pole and associated concrete footing design must be engineer certified to support
the light fitting and to withstand wind loads appropriate to the terrain classification.
Tennis Ball Machines
33. Machines which operate on the air compression principle must not be used after 7.00
p.m. nor before 8.00 a.m.
34. Silent running machines which operate at a noise level not exceeding 10 decibels
(when measured at the property boundary) must not be used after 10.00 p.m. nor
before 7.30 a.m.
Public Safety
35. During operating hours, all parking areas, pedestrian areas and entrances/exits to all
stairwells, lifts, foyers and public toilets must be well lit with vandal resistant lighting
and with intensities to satisfy the requirements of Australian Standard AS1158 “Public
Lighting Code”. Lighting must be designed to reduce the contrast between shadows
and well lit areas. In particular, appropriate security lighting must be provided in the
location of the bicycle/ scooter parking and bin storage area.
36. After hours access to loading docks, storage areas and the basement carpark
(including the vehicle ramp and all stairwells) must be restricted by a security gate,
lockable doors and/or other suitably appropriate means. The basement carpark must
be kept closed and locked at all times while the use is not operating.
Community Management Statement
37. Any proposed Community Management Statement required for the development
pursuant to the Body Corporate and Community Management Act 1997 must be
submitted to Council for endorsement at the same time as submission of the Building
Format Plan (or similar) to Council for compliance assessment.
38. All clauses and by-laws of the proposed Community Management Statement must
accord with the requirements of this Decision Notice.
Water & Sewer Connections
39. An underground connection to reticulated water and sewerage must be provided to the
development site in accordance with the standards and requirements of Northern SEQ
Distributor–Retailer Authority (Unitywater).
40. A Certificate of Completion from the Northern SEQ Distributor–Retailer Authority
(Unitywater) must be submitted to Council that certifies an underground connection to
reticulated water and sewerage has been provided to the development site.
ENGINEERING/TRAFFIC
Site Access and Driveways
41. A sealed access driveway must be provided from the internal service road to all parking
and manoeuvring areas of the development. The works must be undertaken in
accordance with an Operational Works approval and must include in particular:
a. a driveway crossover in accordance with Council’s standard drawing RS-051 and
respective addendum; and