ORDINARY MEETING AGENDA                                                    15 NOVEMBER 2018


    46.   The development must include an internal stairwell connecting the basement level to
          the upper floor. The stairwell must be located and constructed to provide an escape
          route for people to evacuate the basement in the event the barrier and/or pump system
          fails. Plans submitted as part of any subsequent operational works and building permit
          must clearly indicate the stairwell.
    External Works
    47.   Mary Street must be upgraded for the length of its frontage to the subject site. The
          works must be generally in accordance with drawing number 17699-SK100 Revision
          A prepared by TOD Engineers and Project Managers dated 17 August 2018. The works
          must be undertaken in accordance with an Operational Works approval and must
          include in particular:
          a.   construction of new kerb and channelling offset 7.5m (3.5m lane and 4m of cycle
               lane/parallel parking) from the northern side of the existing landscaped median;
          b.   suitable transitions from the new kerb line to join with the existing kerb at the
               western and eastern end;
          c.   landscaping of the verge area;
          d.   construction of a pedestrian footpath in accordance with the conditions of this
               Decision Notice;
          e.   removal of the existing property accesses and reinstatement of the kerb, footpath
               and verge area to match the balance of the site frontage, including the provision
               of topsoil and turf where the existing verge is grassed.
          Condition 47 is imposed pursuant to s145 of the Planning Act 2016 being non-trunk
          infrastructure.
    Site Access and Driveways
    48.   A sealed access driveway must be provided from Mary Street to all parking and
          manoeuvring areas of the development. The works must be undertaken in accordance
          with an Operational Works approval and must include in particular:
          a.   driveway crossovers generally in accordance with Council’s Standard Drawing
               Number RS-051 and any associated addendum.
          b.   suitable safety measures, including warning signage, to improve driver
               awareness of the flood barrier, service vehicles and pedestrians and to enhance
               driver and pedestrian safety. Warning signage must be provided near the exit
               ramp from the underground parking area and the guest/service area to warn
               motorists of pedestrian movement along the frontage street.
    Car Parking
    49.   A minimum of 17 car parking spaces, inclusive of 1 courtesy bus space, must be
          provided and marked on the site and made available and accessible at all times while
          the use is open for business. The works must be undertaken in accordance with an
          Operational Works approval and must include in particular:
          a.   13 customer parking spaces (including 4 scooter spaces) within the total, which
               are clearly marked for that purpose and accessible at all times for visitor use.
          b.   3 staff parking spaces within the total, which are clearly marked for that purpose.
          c.   1 courtesy bus space within the total.
          d.   2 disabled parking space/s within the total.
          e.   dimensions, crossfalls and gradients in accordance with Australian Standard
               AS2890: Parking Facilities.


                                                                                  Page 43 of 47
Log in to download the original file

2018-11-15 Ordinary Meeting Agenda(PDF, 920KB).pdf · 943 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.