Original source · versioned page text
2018-11-15 Ordinary Meeting Agenda
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
ORDINARY MEETING AGENDA 15 NOVEMBER 2018
46. The development must include an internal stairwell connecting the basement level to
the upper floor. The stairwell must be located and constructed to provide an escape
route for people to evacuate the basement in the event the barrier and/or pump system
fails. Plans submitted as part of any subsequent operational works and building permit
must clearly indicate the stairwell.
External Works
47. Mary Street must be upgraded for the length of its frontage to the subject site. The
works must be generally in accordance with drawing number 17699-SK100 Revision
A prepared by TOD Engineers and Project Managers dated 17 August 2018. The works
must be undertaken in accordance with an Operational Works approval and must
include in particular:
a. construction of new kerb and channelling offset 7.5m (3.5m lane and 4m of cycle
lane/parallel parking) from the northern side of the existing landscaped median;
b. suitable transitions from the new kerb line to join with the existing kerb at the
western and eastern end;
c. landscaping of the verge area;
d. construction of a pedestrian footpath in accordance with the conditions of this
Decision Notice;
e. removal of the existing property accesses and reinstatement of the kerb, footpath
and verge area to match the balance of the site frontage, including the provision
of topsoil and turf where the existing verge is grassed.
Condition 47 is imposed pursuant to s145 of the Planning Act 2016 being non-trunk
infrastructure.
Site Access and Driveways
48. A sealed access driveway must be provided from Mary Street to all parking and
manoeuvring areas of the development. The works must be undertaken in accordance
with an Operational Works approval and must include in particular:
a. driveway crossovers generally in accordance with Council’s Standard Drawing
Number RS-051 and any associated addendum.
b. suitable safety measures, including warning signage, to improve driver
awareness of the flood barrier, service vehicles and pedestrians and to enhance
driver and pedestrian safety. Warning signage must be provided near the exit
ramp from the underground parking area and the guest/service area to warn
motorists of pedestrian movement along the frontage street.
Car Parking
49. A minimum of 17 car parking spaces, inclusive of 1 courtesy bus space, must be
provided and marked on the site and made available and accessible at all times while
the use is open for business. The works must be undertaken in accordance with an
Operational Works approval and must include in particular:
a. 13 customer parking spaces (including 4 scooter spaces) within the total, which
are clearly marked for that purpose and accessible at all times for visitor use.
b. 3 staff parking spaces within the total, which are clearly marked for that purpose.
c. 1 courtesy bus space within the total.
d. 2 disabled parking space/s within the total.
e. dimensions, crossfalls and gradients in accordance with Australian Standard
AS2890: Parking Facilities.
Page 43 of 47