Part 9 of 37 Appendix 7 - Stormwater Management MCU12/0208

of 58

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (52.0 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.

Noosa on Weyba
Stormwater Management Plan
                                                                                                     <..f) Carcln                            @




>   Clean out points should be provided for all underdrainage.

>   Litter baskets should be installed on the overflow pits.

The bio-retention filter media was assumed to be sandy loam with a saturated hydraulic conductivity of 200
mm/hr. The extended detention depth was assumed to be 0.3 metres. The filter depth assumed was either
0.6 or 0.8 metres. Transition and drainage layers will also be required underneath the filter media. In areas
outside of the Asset Protection Zone (APZ)the bio-retention basins can be planted with suitable trees such
as melaleucas.           These require a filter depth of 0.8 metres. The advantage of planting trees in bio-retention
basins is that they improve the aesthetics and bio-diversity.                    They also reduce the likelihood of blockage of
the filter media. Recent studies have shown they do not increase the risk of blockage of the underdrainage.

A typical bio-retention basin cross-section is shown in Image 1.




                                                                                                                   Overflow Weir
                                                                                                             ~

                                Clean Out Point



 Inlet Pipe

                                                                                                      0.3m Extended Detention Depth




              Concrete Lined
              Coarse Sediment                                                                         0.6m Filter Media (Sandy Loam)
              Forebay



                                                                                                      0.1 m Transition Layer (Coarse Sand)


                                                                                                     ~0.2m Drainage Layer (Fine Aggregate)



                                Geotextile Fabric
                                                                Underdrainage          Outlet Pipe

                                                                (0.50/0 slope)




Image 1                  Typical Bio-retention Basin Cross-section

6.2.3              Bio-retention Gardens

Bio-retention gardens are similar to bio-retention basins, except that they are smaller in size and located
within the road reserve, and so can be incorporated into the landscaping. They treat runoff from surrounding
areas before it is        discharged to the stormwater pipes.

They are effective treatment devices in relatively flat and low-lying areas as they do not need as much
vertical differentiation.

The bio-retention filter media was assumed to be sandy loam with a saturated hydraulic conductivity of 200
mm/hr. The extended detention depth was assumed to be 0.15 metres. The filter depth assumed was 0.8
metres, to allow for the planting of trees.            Transition and drainage layers will also be required underneath
the filter media.

A typical bio-retention garden will have a filter area of 9 m2 and a surface area of around 20 m2 to allow for

batters, coarse sediment forebay and field inlet. They will each treat runoff from every two lots on average.
Larger gardens will be positioned in areas where there is sufficient space.
The location and               design of the bio-retention gardens will be detailed during the design of the Precincts.
Road reserve widths of at least 15 metres will be necessary to accommodate them. They can be utilised as
traffic calming devices.

To improve the treatment efficiency of the bio-retention gardens the overflow from the rainwater tanks will be
connected directly to the underground               drainage.     This will ensure that relatively clean roofwater is not re-
contaminated, it will improve the drainage efficiency of the road reserve and so reduce the risk of local
flooding. A sensitivity analysis looking at the impact of draining the rainwater tanks to the bio-retention
gardens will be conducted.
For the detailed civil design of each basin the following elements should be included.



Northbrook Corporation Pty Ltd                                   Version 2                                          29 November 2012

SMP_v2.docx                                            Commercial in Confidence                                                    Page 11

Used in these records

About this file

File size
52.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Part 9 of 37 Appendix 7 - Stormwater Management MCU12_0208.pdf · 52.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.