Council archive · source document
Part 9 of 37 Appendix 7 - Stormwater Management MCU12/0208
Very large file (52.0 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Noosa on Weyba
Stormwater Management Plan
~,.., Cardno@
C!lll@11l1:OO ~t::mE ~ ~ ( I
WilliE
(Jmtl o:mt?J [it9;ui3tiHDIlii 0lEn lR9J iiDlJn ~ ~gJllmlii
(Jm1] ~ [Jffi1) ~ (Jml) ~
~ ~ [JQ]
2_F_1 3.240 0.860 100 1.005 60 1.375 35
2_G_1 8.273 2.666 100 1.995 60 3.612 30
2_G_2 0.716 0.716 60
3_H_1 0.607 0.212 100 0.182 60 0.212 30
3_H_2 1.049 0.298 100 0.364 60 0.387 35
3_H_3 1.963 0.618 100 0.476 60 0.869 36
3_H_4 1.981 0.323 100 0.620 60 1.038 48
3_H_5 1.190 1.190 60
3_1_1 4.018 1.118 100 0.906 60 1.994 38
3_1_2 2.891 0.723 100 0.596 60 1.572 42
3_1_3 3.427 1.011 100 0.634 60 1.782 37
3_1_4 5.242 1.226 100 1.707 60 2.309 39
3_1_5 1.147 0.258 100 0.294 60 0.595 43
4_K 0.665 0.150 100 0.154 60 0.361 43
4_L 4.473 1.566 100 1.342 60 1.566 30
Area J is a large rural residential lot. The layout for this area has not yet been defined, but the developed
area is likely to only take up a small part of the area. The most suitable treatment measures will be
determined when this area has been more clearly defined. It is likely that the most appropriate treatment
measures would be rainwater tanks and vegetated swales.
Area A has not been included in the modelling as it is the renovation of an existing building. However, it is
recommended that larger rainwater tanks be installed in this area to reduce the potable water demand.
7.3 Treatment Devices
7.3.1 Rainwater Tanks
The rainwater tanks were set up using the Healthy Waterways MUSIC Modelling Guidelines. It was
assumed that a 10 kL tank would be provided for each residential lot and a 5 kL tank would be provided for
each townhouse or retirement villa. For the proposed apartment buildings a 120 kL tank was used. A
sensitivity analysis will be conducted to determine the impact of only providing half of this tank size.
The rainwater tank usage rates assumed that full water saving devices would be adopted (i.e. 21 LIp/day for
toilet flushing and 26 LIp/day for laundry). The following occupancy rates were assumed:
> 2.8 people per residential lot;
> 2.0 people per townhouse or retirement villa; and
> 1 .7 people per apartment.
For outdoor uses it was assumed that 70 percent of the ground area would be irrigated at 548 mm/year,
which is the rate recommended for private gardens (refer MUSIC Guidelines). The ground area was
assumed to be 300 m2 for premium residential lots and 235 m2 for standard residential lots. For the other
types of development the ground area was taken from the MUSIC model sub-catchment area. The outdoor
use was scaled by PET and rainfall. Therefore on days where there is sufficient rainfall no irrigation would
be applied.
The details of each rainwater tank are shown in Table 7-2.
Northbrook Corporation Pty Ltd Version 2 29 November 2012
SMP_v2.docx Commercial in Confidence Page 15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 9 of 37 Appendix 7 - Stormwater Management MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 52.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.