Council archive · source document
15010_Noosa Council_Decision Notice_221215 · OPW18/0022
Attached to the e-mail Operational Works Application OPW18/0022 - 279 Gympie Terrace, Noosaville.
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
OPW15/0172 Works within Road Reserve/Reinstatement 15. Safe pedestrian access on all streets in the vicinity of the development must be maintained at all times. Should footpath/road closures be necessary to carry out construction works, Council’s Engineering Officer must be notified prior to the proposed closure and all requirements complied with. 16. All frontage works must match neatly with existing road and verge/footpath features. Additional works beyond the frontage may be required to provide an acceptable transition to existing road and verge/footpath profiles. 17. Electrical conduits or other services proposed to be installed within existing and proposed road reserves under existing sealed carriageways, concrete pathways, concrete/sealed driveways or significant vegetation must be installed by boring. Trenching is not permitted, unless specifically approved by Council. Pathways 18. All pathways must be constructed in accordance with the following requirements: a. All footpath/cycleway must comply with Council’s Standard Drawing SEQ R- 065. b. Provision must be made for disabled access at all kerb crossings associated with pathways, in accordance with Council's current standards. c. All paths must have a slip resistant surface d. Expansion and contraction joints must provide a flush finish. Installation of joints by saw cutting is preferred to ensure a smooth ride for cyclists e. The required work includes any modifications to ensure the footpath finishes flush with all existing service covers and the like, or alternatively these services are raised or altered, so as not to create a pedestrian safety hazard f. The existing sealed footpath must be resealed to match the existing width, using an approved asphaltic concrete with a minimum depth of 10mm. Where construction work is not undertaken by council, separate written approval from Council’s Engineering and Environment Assessment Branch will be required prior to the commencement of the resealing work. 19. All elements of the existing path in the frontage of the site must be removed and replaced with the new path. 20. Pathways must: a. terminate in a manner that ensures smooth transition to existing surfaces for public safety b. be designed and constructed to comply with the Disability Discrimination Act (DDA), Access to Premises Standard, Austroads and relevant sections of AS1428 Design for access and mobility Site Access and Driveways 21. Driveway crossovers must be constructed in accordance with council’s Standard Drawing SEQ R-051 Page 5 of 14 Document Set ID: 20003332 Version: 1, Version Date: 22/12/2015 Print Date: 22 December 2015, 3:18 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
15010_Noosa Council_Decision Notice_221215.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.