96. All paths shall be designed and constructed to ensure pedestrian safety using non-slip materials and to
produce an evenly graded surface finish.
Stormwater Drainage
97. A stormwater management plan shall be prepared by a RPEQ, specialising in stormwater and water
quality management incorporating the principles of the Environmental Management Plan for the Settlers
Cove Development 23118 DA, that demonstrates water reuse strategies, infrastructure capacity and
effective treatment methodology. The use of rainwater harvesting tanks for irrigation purposes shall be
incorporated in the overall design plans. These plans shall be submitted to Council for approval prior to
obtaining a Development Permit for Operational Works.
98. All stormwater drainage shall be collected on site and discharged so there is no net increase in
stormwater runoff from the site.
99. On site swale drains will be required to capture and direct any overland stormwater runoff to the Infiltration
Pits proposed on site. These swales shall be sized to carry a 3-month storm event and plans detailing
their capacity, location, length, width and grades shall be submitted to Council for approval.
100. To ensure polluted run-off does not enter any of the proposed Infiltration Pits, and ultimately the water
table, stormwater run-off from the carparking areas and the driveways shall have the first flush (the first 12
mm of rainfall or hose-down) collected in a grease/oil arrestor (or similar device) provided on site prior to
discharging into the infiltration pits.
To this end, a detailed maintenance plan shall be prepared for the proposed grease/oil arrestors, which
shall be submitted to the Council for approval prior to obtaining a Development Permit for Operational
Works.
All other clean stormwater, such as roof water, can be collected on site and discharged directly into the
infiltration pits, bypassing the grease/oil arrestor.
A Development Permit for Building Works shall not be granted until a Development Permit for Operational
Works has been issued in regard to the drainage scheme.
101. All site stormwater drainage shall be by means of a gravity system.
102. Plans of the entire on site drainage design shall be prepared by a Registered Professional Civil Engineer
and submitted to Council prior to obtaining a Development Permit for Operational Works.
Sewer Mains
103. The site shall be connected to Council’s existing sewerage reticulation systems and be constructed in
accordance with Council’s standards and requirements at no cost to Council.
Town Water Supply
104. The site shall be connected to Council’s existing town water supply and be constructed in accordance with
Council’s standards and requirements at no cost to Council.
105. Each water connection to the water reticulation system shall extend to the property boundary and be
metered. Where multiple units are served by a single service, multiple water meters to each individual
unit and for the body corporate shall be installed. All fees for the supply of water meters shall be paid to
the Council.
Service Easements
106. All existing and proposed easements within the site shall be shown on the plans submitted for Operational
Works / Building Works approval.
107. Registered easements shall be created over any Council service within the subject site in accordance with
Council’s requirements (if not already created) and at no cost to Council.
The Applicant’s Solicitor shall give Council’s Solicitor an appropriate undertaking in writing that the Title
Deed and the easement documents will be lodged at the Land Titles Office and any additional Titles
Office forms or requisitions requiring the consent of Council will be attended to promptly.
A duly executed copy of the easement shall be submitted to Council for perusal prior to the use
commencing.
SEP o:\database\onestop\decision.doc
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
23117 DA COMPILED Decision Notice [As Published]Related documentApplication case desk ↗
0015CF9F.001.pdfRelated documentPublic source context ↗
About this file
- File size
- 87 KB (small file)
- File type
No other editions are linked here.