Council archive · source document
09/1382 - Operational Works - Landscaping & Civil Works [As Published] · 142009.1382
Very large file (20.7 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
-6- effective measures to mitigate potential increases in flow levels from the development. Refer Drawing DE07731/02 included in Appendix A for further details. 1.6 Flooding With reference to Noosa Council Natural Hazard: Landslide and Flooding Overlay Map (OM4.3), the subject site is not within the Q100 Flood Prone Area. Refer Appendix A for extract from overlay map. 2.0 RAINWATER REUSE With reference to Noosa Council Designated Rainwater Tank Area Map, the subject site is within an area that requires rainwater tanks. Schedule 8 of the Noosa Planning Scheme requires a minimum storage capacity of 3000 litres per dwelling unit. In addition, water from the rainwater tanks is to be used for. a) Flushing of toilets internal to the building; b) Extemal irrigation, topping up of swimming pools or water features and outside cleaning. All rainwater tanks are to be designed and installed as per the Queensland Development Code (QDC), Part 25 — Rainwater Tanks. Refer Duke Environmental Drawing DE07731/02 in Appendix A for proposed location of rainwater tanks. 3.0 HYDROLOGY 3.1 Methodology It is proposed to mitigate the effects of the proposed development on stormwater discharge rate by way of incorporating a Detention Basin. This system is proposed to capture runoff from the site to maintain design discharges up to, and including, the 100 year ARI event, from pre to post development scenarios (non-worsening). Refer to Drawing DEO7731/02 included in Appendix A for details. Three different hydrological cases were investigated for the purpose of this study: Case 1: Pre-Development site (existing) Case 2: Post-Development of site (without mitigation) Case 3: Post Development with mitigation strategies implemented (Detention Basin) The XP-RAFTS Run-off Routing Software was used for hydrological analysis of the pre and post development catchments. Table 4.1 summarises adopted discharge rates for the design critical storm duration, and the corresponding rational method discharge. Refer Appendix B for internal site hydrologic calculations and variables. 4A07731SMP January 2008 ATijs oe ge ieee
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/1382 - Operational Works - Landscaping & Civil Works [As Published]Related documentApplication case desk ↗
About this file
- File size
- 20.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.