Unit Building. Sunshine Beach Geotechnical Investigations The design of piled foundations should include assessment of both strength and serviceability limit states. A geotechnical strength reduction factor of ©, = 0.65 should be applied to the ultimate strength values when considering the ultimate strength limit state. Where driven piles are adopted, should a suitable proportion be dynamically tested, a higher geotechnical strength reduction factor of ®, = 0.7 may be adopted. The geotechnical design parameters for pile design are a function of pile type, size, load and depth. The type and size of piles in turn depends on the relative cost of altemate piling systems and sizes. The most cost effective piling system can be designed by your piling contractor based on the Coffey borehole logs. Excavations Soils on the site to a depth of 3 metres may be excavated with conventional earthmoving equipment. Temporary open excavations in the medium dense to very sands should be battered back at a slope not steeper than 1.5 horizontal to 1 vertical where the excavation is above the water table and 3 horizontal to 1 vertical for excavations below the water table. Alternatively, engineered support systems must be adopted. Basement Retaining Wall Design Geotechnical parameters for retaining wall design are as follows:- Soil internal Angle of Friction 30 degrees Base Soil Angle of Friction 33 degrees Soil Unit weight 20 KN per cubic metre Minimum Depth of Toe Footing 0.5 metres Minimum Width of Toe Footing 0.6 metres Allowable Bearing Capacity Founding not recommended in loose sands. See above 100 kPa in medium sands to a depth of 2.4 metres 160 kPa in dense sands at depths greater than 2.4 metres Propped basement walls retaining drained sand or gravel may be designed assuming a rectangular pressure distribution with a maximum earth pressure of GH kPa acting over the wall where H is the total depth of excavation in metres. Where the sand or gravel backfill is undrained, the triangular hydrostatic pressure distribution must be added to the earth pressures. This does not take into account any additional lateral earth pressures produced by surcharges such as landscaping, adjacent structures or vehicles or heavy equipment. Lateral pressures due to shrink swell can be ignored. Coffey Geotechnics 4 GEOTKPAR13340A/A 22 January 2008 ao hae wb +
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/1382 - Operational Works - Landscaping & Civil Works [As Published]Related documentApplication case desk ↗
About this file
- File size
- 20.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.