Original source · versioned page text
MCU -Cooroy
Noosa Council documents MCU15/0111 77. The requirements of ENERGEX shall be satisfied in relation to any existing services traversing the site. Written confirmation by ENERGEX that satisfactory arrangements have been made to formalise any required easements and/or existing informal services shall be submitted prior to Council endorsing the Plan of Survey. 78. Streets lighting and pathways lighting throughout the development site must be provided in accordance with Australian Standards. 79. Street lighting shall be provided along Pearsons Road frontage of the site in accordance with Australian standards. Telecommunication 80. The requirements for TELECOMMUNICATION services shall be satisfied in relation to the provision of new telephone services to the developed site. In this regard written confirmation from an approved telecommunication agency shall be submitted to the Council prior to Council endorsing the Plan of Survey. Erosion and Sediment Control 81. Any person acting on this permit shall prevent erosion and sediment export from leaving the site. Site control measures such as silt fencing, controlled gravel access to the site and controlled disposal of waste, will be necessary. In this regard plans detailing the methods of controlling erosion and sediment are required to be submitted to the Council for approval prior to obtaining a Development Permit for Operational Works. General 82. A suitably qualified Registered Professional Engineer shall prepare engineering drawings and specifications for all engineering works that will become Council infrastructure, which shall be submitted in conjunction with an application for a Development Permit for Operational Works. In this regard a DXF/DWG file on GDA94 zone 56 grid of the proposed cadastre layout is to be submitted in conjunction with any application for Operational Works. 83. Digital detailed designs including drawings, calculations, specifications and a schedule of works, shall be submitted with any application for a Development Permit for Operational Works in respect of roadworks and stormwater drainage works. The design shall be in accordance with Council’s Planning Scheme Policy PSP05 — Engineering Design Standards — Roads, Drainage and Earthworks. To avoid conflict with underground pipes or services, all existing and proposed services required by the development shall be shown on the plans. 84. To facilitate production of As Constructed drawings it is suggested that all design drawings are submitted in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of ADAC are available at www.adac.com.au). 85. Aconstruction management plan/strategy shall be prepared by a suitably qualified Registered Professional Engineer and submitted to Council in conjunction with any application for Operational Works. The construction management plan shall ensure no damage occurs to Council services and that any adverse impact on the local area due to the construction works is within the acceptable limit and properly managed to the satisfaction of Council. Page 12 of 37 Document Set ID: 20103451 Version: 1, Version Date: 25/07/2016 Print Date: 25 July 2016, 3:34 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (MCU -Cooroy.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.