Log in to see the plans as drawn Effects of Use Table 9.3.11.3 Criteria for assessment (part)
Performance outcomes Acceptable Outcomes
Effects of Use
PO2
Sufficient separation distance is provided between Infrastructure No acceptable outcome provided
activities and incompatible uses on the same site and
neighbouring premises to maintain amenity for neighbouring
uses.
PO3
Infrastructure activities have minimal effect on adjoining premises No acceptable outcome provided
and on scenic amenity by way of noise, reflection, glare, or any
other emission.
Design requirements Table 9.3.11.3 Criteria for assessment (part)
Performance outcomes Acceptable Outcomes
Design requirements
PO4
The siting and design of buildings or structures associated with No acceptable outcome provided
the infrastructure activity i s compatible with the setting and
character of the local area.
PO5
Infrastructure activities are sited and designed to: No acceptable outcome provided
(a) minimise adverse visual impacts beyond the boundaries of
the site; and
(b) minimise adverse impacts on the amenity of nearby
residential, community or other sensitive land uses.
PO6 AO6.1
Mechanical plant and equipment (including air conditioning Plant and equipment are:
equipment) are: (a) setback at least 6 metres from any property boundary; and
(a) positioned to minimise adverse impacts on the amenity of (b) screened by a 1.5 metre wide vegetated buffer of dense
any adjoining sensitive land uses; vegetation or fencing of 1.8 metre in height.
(b) enclosed or designed and positioned to visually integrate
with building and roof design; and OR
(c) appropriately screened.
AO6.2
Plant and equipment are located within a building.
PO7 AO7.1
Solar farms or roof mounted photovoltaic panels totalling over Photovoltaic solar panels are:
300m2 do not create glare nuisance to roads or surrounding (a) setback at least 20 metres from property boundaries; and
areas.
(b) screened by a 1.5 metre wide vegetated buffer of dense
vegetation on property boundaries, including tall trees.
AO7.2
Photovoltaic solar panels are constructed of dark, lightabsorbing
materials and covered with an antireflective coating enabling as
much light as possible to be absorbed and minimising glint and
glare.
PO8 AO8
Infrastructure activities provide an attractive street front address Where located within urban boundaries:
NOOSA PLAN 2020 Page 64 of 150