Original source · versioned page text
MCU14/0106 & OPW15/0001 Town Planning Report & Appendix A Code Compliance
Original PDF page 204, section 1. The text section number identifies this passage in the reader.
Town Planning Report
28 Eenie Creek Road, Noosaville and parts of the road reserves of Hofmann Drive and Walter Hay Drive
Performance Outcomes Acceptable Outcomes Response
AO1.9 Development below or abutting a railway viaduct is to be clear of R1.9 Complies
permanent structures or any other activity that may impede emergency The proposed development is not located within the vicinity of a
access or works and maintenance of rail transport infrastructure. railway.
Editor’s note: Temporary activities below or abutting a railway viaduct
could include, for example, car parking or outdoor storage.
PO2 Development prevents unauthorised access to: AO2.1 Fencing is provided along the property boundary with the railway. R2 Not Applicable
(1) state transport corridors, Editor’s note: Where fencing is provided it is to be in accordance with the The site is not within the vicinity of a state transport corridors, future
(2) future state transport corridors, railway manager’s standards. state transport corridors or state transport infrastructure.
(3) state transport infrastructure, AND
by people, vehicles and projectiles. AO2.2 Accommodation activities with a publicly accessible area located
within 10 metres from the boundary of a railway or 20 metres from the
centreline of the nearest railway track (whichever is the shorter distance),
include throw protection screens for the publicly accessible area as
follows:
(1) openings of no greater than 25 mm x 25 mm
(2) height of 2.4 metres vertically above the highest toe hold if see-
through, or 2 metres if non see-through.
Editor’s note: Expanded metal is considered see-through.
AND
AO2.3 Development in a railway or future railway land includes throw
protection screens.
Editor’s note: Throw protection screens in a railway or future railway land
designed in accordance with the relevant provisions of the Civil
Engineering Technical Requirement CIVIL-SR-005 Design of buildings
over or near railways, Queensland Rail, 2011, and the Civil Engineering
Technical Requirement CIVIL-SR-008 Protection screens, Queensland
Rail, 2011, comply with this acceptable outcome.
AND
AO2.4 Built to boundary walls and solid fences abutting a railway are
protected by an anti-graffiti coating.
AND
AO2.5 Road barriers are installed along any proposed roads abutting a
railway.
Editor’s note: Road barriers designed in accordance with Queensland Rail
Civil Engineering Technical Requirement CIVIL-SR-007 Design and
selection criteria for road/rail interface barriers comply with this acceptable
outcome.
AND
AO2.6 Proposed vehicle manoeuvring areas, driveways, loading areas or
carparks abutting a railway include rail interface barriers.
December 2014 Cardno HRP A123