Council archive · source document
MCU Application Report · 51997.2283.02
PO Box 432 POMONA QLD 4568 Ph 07 3063 9391 [email protected] ABN: 49 162 782 014
Performance Outcomes Acceptable Outcomes
1C
AO20.4
Planter boxes, screens, pergolas, landscaping and
architectural design of balconies are used to screen
the ground floor private open space of dwellings from
separate upper level dwellings.
Editor's note—refer to figure AP3-1A
AO20.5
Permanently fixed external screening devices
complement the building's external materials and
finishes and may incorporate solid translucent
screens, shutters, perforated panels or trellises which
have a maximum of 50% openings.
Editor's note—refer to figure AP3-1B
PO21 AO21.1 NA
Mechanical plant, vehicle manoeuvring, Communal outdoor recreational facilities including
utilities and communal outdoor swimming pools, spas and sports courts are:
recreation uses:
1. do not have an adverse effect on the 1. setback at least 12 metres from the boundary
amenity enjoyed by users of adjacent of land in a residential zone and screened by
or nearby premises through emission a 5 metre wide buffer densely planted with
of noise, light, fumes or smoke; and trees and shrubs including species from 1
2. do not cause unreasonable metre to 8 metres in height; or
disturbance to local fauna through 2. located internally to the arrangement of
light or smoke emissions. buildings on the site; and
3. not used between the hours
of 9:00pm and 6:30am the following day.
AO21.2
For a lit sports court:
1. the court is located at least 60 metres from
the external wall of an existing or approved
dwelling on adjoining or nearby premises (as
measured from the centre line of the court);
and
2. the vertical illumination resulting from direct,
reflected or other incidental light emanating
from the site does not exceed 8 lux when
measured at any point 1.5 metres outside the
boundary and at any level from ground level
upward; and
3. any floodlighting is restricted to the types that
give no upward component of light were
mounted horizontally (i.e. a full cut off
luminaire).
AO21.3
Mechanical plant is-
1. located at least 2 metres from the side or rear
property boundaries;
2. where located at ground level, screened by
fencing 1.5 metres in height or dense
vegetation of at least 1.5 metres in width
incorporating grouped trees and shrubs with a
maximum separation distance of 1 metre
measured from the centre of the plant;
3. where located above ground level, enclosed or
screened such that it is not visible from the
street frontage nor adjoining properties; and