Performance outcomes                                            Acceptable Outcomes
Kin Kin Business and Industry Precinct                          Kin Kin Business and Industry Precinct
PO17                                                            AO17
Buildings and other structures present a high quality           With the exception of class 10 buildings or structures,
streetscape with building elements and forms that—              buildings—
(a)   are consistent with the bulk and scale of buildings on     (a)     have a floor plan predominantly comprising square or
      adjoining and nearby land;                                       rectangular shapes;
                                                                 (b)     have a front elevation—
(b)   contribute to the historical village context;
                                                                         (i)  parallel to the front boundary;
(c)   create pedestrian scale and visual interest;                      (ii)  where the first floor presents balconies or
(d)   integrate landscaping into the building design and car                  awnings to the street;
      parking areas;                                                   (iii)  with recessed or framed windows and doorways;
(e)   retain and enhance the Queensland vernacular built         (c)    have sunhoods to windows and other openings; and
      form; and                                                  (d)     have a roof pitch no less than 12 degrees with a
                                                                       minimum of 600 millimetre eaves to 75% of the
(f)   retain and enhance the open streetscape and lack of
                                                                       building.
      formal boundaries between public and private lands.
                                                                Editor’s Note — a 450 millimetre eave with a 150 millimetre
                                                                gutter meets a 600 millimetre eave requirement.
Adaptability
PO18
Buildings are designed to provide for a range of potential users No acceptable outcome provided
by allowing for adaptable floor designs and adequate floor to
ceiling heights.
Mechanical plant, equipment and storage
PO19                                                             AO19.1
Mechanical plant and equipment (including air conditioning       Mechanical plant, refuse and recycling area, vents and
equipment) and storage areas are designed and located to:        exhausts are not visible from a street, public space or
(a)    avoid adverse visual impacts when viewed from the         adjoining residential use and is acoustically screen from
       street and adjoining properties; and                      adjoining sensitive land use.

(b)   visually integrate with the building design.
                                                                AO19.2
                                                                Mechanical plant and equipment are:
                                                                (a)    located more than 2 metres from any property
                                                                       boundary;
                                                                (b)    where located at ground level, screened by fencing 1.5
                                                                       metres in height or dense vegetation of at least 1.5
                                                                       metres in width incorporating grouped trees and shrubs
                                                                       with a maximum separation distance of 1 metre
                                                                       measured from the centre of the tree or shrub;
                                                                (c)    visually integrated into the line and plane of the building
                                                                       and roof design and do not project beyond the height or
                                                                       width of the building when viewed from the street and
                                                                       adjoining properties; and
                                                                (d)    fully enclosed or screened where above ground level
                                                                       such that they are not visible from the street frontages
                                                                       nor adjoining properties.




                                                                                                                    Page 408 of 1290
                                                                                                                            Page 8 of 26

Log in to download the original (62f8d7f274.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.