Original source · versioned page text
Planning Application
Attached to the e-mail REC16/0007 Boundary Realignment Application - 183 Blanckensee Road, Black Mountain.
iii. adversely affecting the flow of water to
in any overland flow path. accept any additional loading;
AND
S12.3 Car parking and maneuvering
areas are constructed at a level that
permits the parking area to drain from
the site by gravity means, without the
need for mechanical pumping; or
S12.4 Basements for residential uses
have flood immunity above the Q100
where alternative means to mechanical
pumping are used to achieve such
immunity; or
S12.5 Basements for non-residential
uses have flood immunity above the
Q100 that may be achieved by means
of mechanical pumping where the
mechanical feature is installed with
adequate holding tanks and an
alternative back up power source.
Sloping sites S13.1 Buildings are of split level The proposal does not involve
O13 On sloping sites, buildings and design that step down the slope or the establishment of buildings or
structures are designed to maximise the have a suspended floor construction; structures.
use of natural slope and minimise the (See Figure 8.1 below) AND
need for cut and fill. S13.2 Cut or fill is less than 2m in
depth;
AND S13.3 The distance between the
ground and the lowest part of the floor
of the building does not exceed 3m.
Figure 8.1—Design for sloping sites
(suspended floor)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.