Council archive · source document
Request for Further Information - 010.2009.00000882.001 [As Published] · 132009.882
-2-
Engineering
Note - Compliance with Council’s Codes and Planning Scheme Policies is required,
particularly the following codes and policies are considered most relevant to the
proposed development:
Driveways & Carparking Code,
Earthworks Code;
Existing Services Code;
Transport, Roads & Drainage Code;
Water Sensitive Design Code;
PSP 5 - Engineering Design Standards - Roads, Drainage and Earthworks; &
PSP 6 – Engineering Design Standards Water & Sewerage.
Whilst a detailed assessment of these Codes will take place at the Operational Works
stage, it is important that the development considers these Codes and Policies prior
to obtaining a Material Change of Use approval, as they may impact on the proposal.
2. Provide an accurate survey plan of the site (including the immediate surrounds) that
incorporates:
2.1 Contours lines at hight interval not exceeding 0.5m.
2.2 Existing trees.
2.3 Existing structures, buildings and fences.
2.4 Existing services: sewer mains, stormwater pipelines and structures, water,
telecommunication and power poles including those within the road reserve
and adjacent to the site.
2.5 The edges of bitumen and kerb line and barrier along the service road.
3. Provide a general design of the proposed vehicle access to the site and proposed
parking spaces showing the grades and finished levels of the driveways.
4. Please provide engineering design plans to show the depth of excavation and the
detail of the retention method to be used on development site. The design shall also
demonstrate that the excavation and retention method will not adversely impact on
the structural integrity of the existing sewer main or compromise access to this main
for maintenance purposes and/or upgrading works.
5. Provide a plan, with relevant dimensions verifying all buildings and structures
including masonry walls, roof overhang and stairwells are located a minimum of 1.5
metres from the nearest part of Council’s sewerage infrastructure. Councils Planning
Scheme Codes require a minimum clearance of 1.5 metres from the nearest part of
the council sewer to the outermost projection of any building or structure.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Request for Further Information - 010.2009.00000882.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 18 KB (small file)
- File type
No other editions are linked here.