MCU22/0051 Application For Material Change Of Use Hardware & Trade Supplies At 178 Eumundi Noosa Road, Noosaville · Attachment 1 - MCU220051 – Proposed Conditions

of 7

Page text shows just the words. Original shows the document exactly as it was published.

      External Works
22.   Gateway Drive must be upgraded for the length of its frontage to the subject site allowing for
      suitable transition of works. The works must be undertaken in accordance with an
      Operational Works approval, the approved plans of development and must include in
      particular:
      a.   A road reserve dedication in favour of Council, maintaining a minimum verge width of
           5m along the development frontage.
      b.   Modification of the existing pavement marking to extend the channelised right turn lane
           (CHR).
      c.   Extension of the existing yellow line marking “No Stopping” zone.
      d.   Construction of a pedestrian footpath in accordance with the conditions of this Decision
           Notice.
      Condition 22 is imposed pursuant to s145 of the Planning Act 2016 being non-trunk
      infrastructure.
      Site Access and Driveways
23.   Sealed access driveways must be provided from Gateway Drive to all parking and
      manoeuvring areas of the development. The works must be undertaken in accordance with
      an Operational Works approval and must include in particular:
      a.   Driveway crossovers in accordance with IPWEA Standard Drawing RS-051 and the
           approved plans of development.
      b.   Provide signage and line marking in accordance with the Department of Transport and
           Main Roads Manual of Uniform Traffic Control Devices (MUTCD) that clearly denotes
           separate entry and exit driveways for the development.
      Car Parking
24.   A minimum of 57 car parking spaces must be provided and marked on the site and made
      available and accessible at all times while the use is open for business. The works must be
      undertaken in accordance with an Operational Works approval and must include in particular:
      a.   Provision of vandal resistant public lighting with intensities to satisfy the requirements
           of Australian Standard AS1158: Public Lighting Code;
      b.   One (1) disabled parking space/s within the use area;
      c.   Dimensions, crossfalls and gradients in accordance with Australian Standard AS2890:
           Parking Facilities.
25.   All car parking areas and access driveways must be maintained exclusively for vehicle
      parking and manoeuvring and kept in a tidy and safe condition at all times.
26.   Directional signage must be provided to direct visitors and customers to the car parking
      spaces provided on site.
      Paving Treatment of Vehicle Movement Areas
27.   Alternative materials, patterns, or threshold treatments must be used to articulate the
      pavement treatment of vehicle movement areas.
      Pedestrian and Bicycle Facilities
28.   Pedestrian and bicycle facilities must be provided for the development. The works must be
      undertaken in accordance with an Operational Works approval and must include in particular:
      a.   A two metre wide concrete footpath within the road verge for the entire length of the
           site’s frontage to Gateway Drive and connecting to the existing path fronting Lot 11
           SP170295.
      b.   Pedestrian pathways between the proposed car parking area and the building/s.
Log in to download the original file

ATTACHMENT 1 - MCU220051 – PROPOSED CONDITIONS.pdf · 101 KB (small file)