Attachment 16- Amended Stormwater Management Plan MCU12/0208

of 66

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
Noosa on Weyba
Stormwater Management Plan



Batter slopes of 1 in 6 have been assumed for bio-retention swales adjacent to roads. For other bio-
retention swales batter slopes of 1 in 4 have been used.
Bio-retention swales are proposed adjacent to the lake buffer zone in Area B. To better simulate natural flow
patterns several underdrainage outlets will be located along the length of the swale, which will discharge
treated stormwater directly to the lake. Several rock check dams will be located along the length of the swale
where some of the overflow will be discharged across the adjoining lake buffer. Appropriate scour protection
will be required in these areas. The stormwater treatment zone has a width of 10 metres. Based on natural
surface levels the width of the swale required would be around 7 to 8 metres. Further details are provided in
Section 8.

6.2.5          Litter Baskets
As the proposed development is a community title scheme the maintenance of stormwater quality devices
will be the responsibility of the body corporate. In standard residential developments litter baskets would not
be used due to their ongoing maintenance requirements. For further details of the maintenance
requirements refer to Appendix F.
Litter baskets have been proposed on all inlets discharging to downstream waterways so that any excess
litter and gross pollutants not captured by the other proposed WSUD measures is retained on site and not
discharged downstream. Litter baskets will therefore be required in bio-retention gardens, bio-retention
gardens, bio-retention swales and vegetated swales.
They have an advantage over in-ground gross pollutant traps (GPTs) in that litter is stored in a dry state,
which reduces the risk of dissolved pollutants being discharged downstream. The maintenance of litter
baskets is also more straightforward. They are designed not to impact on the hydraulic efficiency of the gully
or field inlets in which they are installed.
The Ecosol RSF 100 is a typical example of a litter basket that could be used on site.




Northbrook Corporation Pty Ltd                    Version 4                                   16 September 2013
SMP_v4.docx                                 Commercial in Confidence                                   Page 17

Used in these records

About this file

File size
10.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 16- Amended Stormwater Management Plan MCU12_0208.pdf · 10.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.