Attachment 16- Amended Stormwater Management Plan MCU12/0208
Plans and drawings: the text below has words only, no drawings.
Noosa on Weyba
Stormwater Management Plan
7 MUSIC Modelling
7.1 Summary
MUSIC Version 5.1.16 was used in the analysis. The MUSIC Modelling Guidelines for South East
Queensland (Healthy Waterways, 2010) were used as the main reference to set up the models.
The rainfall data was taken from Cooroy Composite (40059) for the 10 year period from the 1/1/1973 to
31/12/1982. A 6 minute time step was adopted.
The MUSIC model layouts for each precinct are shown in Appendix E.
7.2 Catchment Areas
The sub-catchment areas are shown in Figure 2.
The rainfall runoff parameters and pollutant export parameters were taken from Tables 3.7 and 3.8 of the
MUSIC Modelling Guidelines.
For the existing case a rural-residential node was used, with a 0 percent impervious value. For the
developed case an urban-residential nodes were used, except for a small area of commercial development
in Area C. The residential areas were assumed to be 60 percent impervious, townhouses, apartments and
retirement living areas were assumed to be 70 percent impervious.
The breakdown of road, roof and ground area was based on the concept masterplan layout. For precincts
where the layout has not been specified typical surface type splits from Table 3.3 of the manual were used.
2
The roof area of premium residential lots was assumed to be 250 m , and the roof area for standard
2
residential lots was assumed to be 215 m in accordance with Table 3.3. All of the available roof area will be
connected to rainwater tanks so as to maximise stormwater harvesting on site.
The new access roads have been included in the MUSIC modelling. The upgrade of existing Council roads
will be undertaken on behalf of Council or by Council, at a cost to the development. These roads will be
provided with best practice stormwater quality treatment. These road upgrades have not been included in
the MUSIC modelling.
The breakdown of each sub-catchment is shown in Table 7-1.
Table 7-1 MUSIC Sub-catchments
Catchment Total Area Roof Road Ground
Name (ha) Area Percent Im- Area Percent Im- Area Percent Im-
(ha) pervious (ha) pervious (ha) pervious
(%) (%) (%)
1_B_1 1.200 0.425 100 0.161 60 0.614 32
1_B_2 1.948 0.525 100 0.566 60 0.857 36
1_B_3 0.555 0.225 100 0.330 33
1_B_4 1.280 0.325 100 0.490 60 0.465 32
1_B_5 0.895 0.325 100 0.112 60 0.458 32
1_B_6 0.139 100 0.139 60
1_C_1 1.264 0.442 100 0.379 70 0.442 30
1_D_1 3.911 1.369 100 1.173 70 1.369 30
1_D_2 0.833 0.833 60
1_D_3 0.278 0.278 60
1_E_1 3.174 1.111 100 0.952 70 1.111 30
Northbrook Corporation Pty Ltd Version 4 16 September 2013
SMP_v4.docx Commercial in Confidence Page 18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 16- Amended Stormwater Management Plan MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 10.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.