Noosa Civic
Construction Environmental Management Plan



 Tasks                                Actions / Monitoring                                                                        Timing              Responsibility
                                      spillage or seepage has not occurred and that the integrity of the containment area is
                                      not compromised.
                                      Formally audit storage area of dangerous/hazardous substances weekly and record
                                      appropriately.
 Ensure storage and handling of       Ensure site induction training includes appropriate information regarding the storage       During       site   Contractor
 dangerous         or     hazardous   and handling of hazardous substances, including instructions on emergency spill             inductions
 materials (e.g. refuelling) occurs   response procedures and the location of spill response kits.
 at the site camp or as far as
 practicable away from any woody      Storage of hazardous materials shall occur as far as practicable from local creeks and      Ongoing
 vegetation or waters to protect      other waters (including stormwater drains).
 the receiving environment in the     Refuelling shall only occur in pre-existing designated refuelling areas, located at least
 event of a spill.                    50m away from local creeks or drains, and preferably offsite.
                                      Ensure appropriate and sufficient spill cleanup materials are available at all times.
                                      Maintain a record of any accidental release or spillage of hazardous materials
                                      including details or corrective actions undertaken. Immediately report any such
                                      incident to the Principal.
                                      Notify the Principal and relevant administering authority in the event of an accidental
                                      release of hazardous materials from the site with the potential to cause environmental
                                      harm.
 Record keeping.                      Ensure all records and reports are made available to relevant administering authorities     Ongoing             Contractor
                                      upon request.
 Corrective actions.                  Should there be non-compliance with the stated performance indicators the following         Ongoing             Contractor
                                      corrective actions are to be implemented:
                                            identification of the cause of the non-compliance;
                                            implementation of appropriate mitigation measures as determined by the
                                             Principal in consultation with the Contractor and relevant experts (where
                                             required); and
                                            relevant validation monitoring to confirm that the nominated corrective
                                             actions have been effective.
                                      The Contractor shall implement the corrective action(s) as required within the agreed
                                      timeframe noted on the CAR.




Noosa Civic                                                                   Version 1                                                                November 2014
Appendix B - Construction EMP.docx                                                                                                                          Page 21
Log in to download the original file

MCU14_0106 Appendix E - Engineering Report.pdf · 24.1 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.