NOOSA COUNCIL IDAS Development Application Decision Notice                                                   7 of 12


      If no agreement was reached between the two parties (ie the applicant and the owner/s of no. 40
      Elizabeth Street) then the existing sewer connection (approximately 13m long) shall be upgraded to sewer
      main standard at the applicant’s expense.
      A Development Permit for Operational Works shall be required.
40.   To ensure Council’s sewer main is accessible for maintenance purposes and is protected from risk of
      damage no structures requiring a building permit (eg. buildings, swimming pools, retaining walls
      exceeding 1m in height, raised terraces, etc) shall be constructed within this ‘zone of influence’ or within
      1.5m of the centreline of any existing or proposed sewer main, whichever is the greater. As such the
      applicant shall ensure the compliance of Operational Works plans and Building plans to this requirement
Easements for Sewer
41.   A registered easement shall be created over the zone of influence of all existing and proposed sewers
      within the subject site including sewer manholes and over those parts of the subject site that are impacted
      upon by sewers on any adjoining sites. The easements shall generally be parallel to and centred over the
      sewer main and be equivalent in width to twice the depth to invert level of the sewer at the deepest point
      within the allotment (measured from the finished surface) and be no less than 3.0m wide overall. In this
      regard a licensed surveyor shall accurately locate all sewer mains and determine the necessary width of
      the easement, which shall be shown on any plans submitted for Operational Works / Building Works
      approval. To this extent the surveyor shall certify that the sewer and the zone of influence is wholly
      contained within the easement to be created.
      In addition to this the Applicant’s Solicitor shall give Council’s Solicitor an appropriate undertaking in
      writing that the Title Deed and the easement documents will be lodged at the Land Titles Office and any
      additional Titles Office forms or requisitions requiring the consent of Council will be attended to promptly.
      A duly executed copy of the easement shall be submitted to Council for perusal prior to the use
      commencing.
      Any changes required by Council’s Solicitor must be corrected immediately.
42.   No building or other structure shall be constructed or encroach over an easement.
Town Water Supply
43.   The site shall be connected to Council’s existing town water supply and be constructed in accordance with
      Council’s standards and requirements at no cost to Council.

44.   Each individual water connection to the water reticulation system shall extend to the property boundary
      and be metered. All fees for the supply of water meters shall be paid to the Council.

45.   All water meters must be located outside the property boundary and in an easily assessable location to
      facilitate unhindered reading by Council and/or Council’s contracted water meter readers, and not behind
      fences or locked gates. In this regard approval of the water meter configuration and location must be
      obtained from Council’s Water & Sewerage Capital Works Manager prior to lodgement and approval of
      hydraulic drawings.
      Where capable of being separately rated, each dwelling unit shall be served by individual water meter.

Earthworks
46.   Filling works required on site shall be carried out in accordance with Section 3.8 of Council’s Engineering
      Design Standards Manual and so as not to cause the additional ponding of water on any adjoining lands
      or the blockage of, or interference with, any natural surface runoff. Detailed site surveys indicating the
      existing surface levels and contours of the adjoining properties must be provided with the application for a
      Development Permit for Operational Works for Filling and Drainage.
      This may require the design and construction of drainage pipes and/or an overland flow-path within the
      development site that caters for drainage from the adjoining sites for a design storm with an Average
      Recurrence Interval of 1 in 100 years. A private easement for the Drainage of Water encompassing the
      drainage pipes or overland flow-path will also be required. In this regard a Development Permit for
      Operational Works shall be obtained.
      Should evidence certified by a Registered Professional Engineer be provided to Council indicating that no
      additional ponding of stormwater will occur on the adjoining properties the requirement for the drainage
      pipes, overland flow-path and easement shall not apply.
47.   Earthworks carried out on site shall not affect the structural integrity of any of the existing fences or
      structures that border the development site. Fences that are affected shall be replaced prior to the
      Building Certifier issuing the Certificate of Classification. In this regard any fences to be replaced shall be
      clearly shown on the plans submitted for Operational Works approval.




AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@1006ad04\@[email protected]

Used in these records

About this file

File size
59 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

0015E678.001.pdf · 59 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.