Attachment 9- Amended Bushfire Assessment Report MCU12/0208

of 77

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (11.7 MB): the original may take a few minutes to open or download. The page text below is quick to read.

Noosa on Weyba
Bushfire Assessment Report



4.1                Buildings and Structures
The SPP 1/03 Guideline states that, for all development, buildings and structures on lots greater than
      2
2,500m :
            a)     are sited in locations of lowest hazard within the lot; and
            b)     achieve setbacks from hazardous vegetation of:
                               1.5 times the predominant mature canopy tree height or 10 metres, whichever is the
                                greater; and
                               10 metres from any retained vegetation strips or small areas of vegetation; and
            c)     are sited so that elements of the development least susceptible to fire are sited closest to the
                   bushfire hazard.
With respect to the above, the following aspects of the proposed Noosa on Weyba project are noted.
1.       The Noosa on Weyba project is based on a Body Corporate model and as such there would be no
                                                                                                        2
         subdivision (reconfiguration) of existing lots to create new lots with an area less than 2,500m .
2.       Based on actual measurements of existing vegetation within various sectors of the Noosa on Weyba
         project site within and adjacent to proposed urban development areas, the predominant mature
         canopy height of hazardous vegetation associated with the bushfire hazard areas adjacent to
         proposed residential areas is 15-20m.
3.       The recommended corresponding building setback to adjacent areas of retained hazardous vegetation
         is 30m.
Where urban development is proposed adjacent to hazardous vegetation the Concept Master Plan makes
provision for building setbacks of 30m in most instances. These setbacks are provided by one or more of
the following:
> existing or proposed formed roads;
> Open Space reserves where hazardous vegetation will be managed by maintaining an open grassy
  understorey; and
> internal building exclusion zones within individual lots.
It is also relevant to note that in the presence of the proposed building setbacks illustrated in the Concept
Master Plan and when assessed in accordance with Method 1 (Table 2.4.5) of AS3959-2009 Construction of
buildings in bushfire prone areas:
> the majority of the proposed building areas within the Noosa on Weyba project site are located more than
  100m from any areas of potentially hazardous vegetation and as such a Building Attack Level (BAL) –
  Low (as defined in AS3959-2009) would apply;
> the balance of the proposed building areas that are located less than 100m from areas of potentially
  hazardous vegetation, which vegetation is typically open forest situated on land with a slope of < 5%
  would have a BAL of between 12.5 and 19; and
> none of the proposed urban areas would be located such that a BAL - Flame Zone would apply.
In respect of existing dwellings located on, and adjacent to, the Noosa on Weyba project site it is noted that:
> the dwelling located on Lot 12 on RP893393, adjacent to Lake Weyba, maintains a 20m wide firebreak
  between areas of potentially hazardous vegetation to the south of the Noosa on Weyba site;
> the dwelling located on Lot 2 on SP179590, adjacent to the Noosa Par 3 Golf Course, also maintains a
  20m wide firebreak between adjacent areas of potentially hazardous vegetation located within the Noosa
  on Weyba site; and
> the multiple dwellings located within the Eumarella Shores development to the immediate south of the
  Noosa on Weyba project site have, based on measurements from high resolution aerial photography,
  maintained fire breaks generally less than 20m in width.


Northbrook Corporation Pty Ltd                               Version 2                                    11 October 2013
Bushfire Assessment Report v2.docx                     Commercial in Confidence                                  Page 11

Used in these records

About this file

File size
11.7 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 9- Amended Bushfire Assessment Report MCU12_0208.pdf · 11.7 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.