Bushfire Assessment Report
For these reasons, where access is greater than 200 metres from a main road or refuge suitable
for occupants and firefighters, a second access arrangement is required which provides
alternative access in a different direction from the main access.”
In respect of this part of Precinct Four it is noted that:
> a building envelope is defined to ensure that appropriate separation is provided between any dwelling and
adjacent areas of potentially hazardous vegetation; and
> two alternative routes of access/egress would be maintained to the west and north to minimise the
potential for entrapment in the event of a bushfire; and
> the Precinct will be serviced by a reticulated water supply; and
> any dwellings constructed in Precinct Four would need to be of a design and materials that complies with
the requirements of AS3959-2009 Construction of buildings in bushfire prone areas.
4.4 Firebreaks and Maintenance Trails
The SPP 1/03 Guideline states that, for development that will result in multiple buildings or lots, firebreaks
are provided by:
a) a perimeter road that separates lots from areas of bushfire hazard and that road has:
- a minimum cleared width of 20 metres; and
- a constructed road width and weather standard complying with local government
standards.
OR
b) where it is not practicable to comply with the above, fire maintenance trails are located as
close as possible to the boundaries of the lots and the adjoining bushland hazard, and the
fire/maintenance trails:
- have a minimum cleared width of 6 metres; and
- have a formed width and gradient, and erosion control devices to local government
standards; and
- have vehicular access at each end; and
- provide passing bays and turning areas for fire-fighting appliances; and
- are either located on public land, or within an access easement that is granted in favour
of the local government and QFRS.
AND
c) sufficient cleared breaks of 6 metres minimum width in retained bushland within the
development (e.g. creek corridors and other retained vegetation) to allow burning of sections
and access for bushfire response.
The Noosa on Weyba Concept Master Plan makes provision for the following.
1. A perimeter and internal road network that:
- separates most of the proposed residential areas from adjacent areas of potentially hazardous
vegetation;
- has cleared widths ranging from 16 to 36m, with widths less than 20m proposed due to the desire
to minimise the loss of native vegetation and fauna habitat; and
- would comply with relevant standards regarding formed widths, gradients and engineering
standards to cater for fire-fighting appliances.
Northbrook Corporation Pty Ltd Version 2 11 October 2013
Bushfire Assessment Report v2.docx Commercial in Confidence Page 13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 9- Amended Bushfire Assessment Report MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 11.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.