PLANNING & ENVIRONMENT COMMITTEE MEETING AGENDA                              7 FEBRUARY 2017


          b.   All relevant Noosa Council Planning Scheme Policies, standard drawings,
               standard specifications and guidelines, particularly PSP 5 – Engineering Design
               Standards – Roads, Drainage and Earthworks.
          c.   The latest version of the Healthy Waterways document “Water Sensitive Urban
               Design Technical Design Guidelines for South East Queensland” for all water
               quality devices to be constructed on site.
          Driveways
    20.   Driveway crossovers must be designed and constructed generally in accordance with
          the approved plans and in accordance with IPWEA standard drawing RS- 051 and
          must have levels and grades that match the levels, width (2m) and the grades of the
          existing concrete footpath without creating trip hazards.
    21.   The following must be complied with during the construction of the required
          crossovers/driveways:
          a.   The driveway width must not exceed 6m at the front boundary line and 9m at
               the kerb line.
          b.   The driveway surfacing must consist of either an approved hot mixed asphaltic
               concrete or patterned/plain concrete and must have a slip resistant surface.
          c.   The driveway must be constructed so as not to concentrate stormwater runoff
               or ponding onto other properties and/or the road verge.
          d.   For public safety, the finish levels of crossover must ensure smooth transition to
               existing surfaces such as the road grassed verge and existing concrete
               pathway.
          e.   Where applicable, underground service conduits for water supply, electricity
               and any other services must be provided as part of the access driveway works.
          f.   Have a minimum clearance not less than 500mm from the lentil of existing
               stormwater drainage inlet pit.
          g.   Have a minimum clearance of 1.0m from any existing power poles, streetlights
               or other signage.
          h.   Have a minimum clearance of 500mm from any Unitywater/Telstra asset,
               unless a written approval is obtained from Unitywater/Telstra and submitted to
               Council.
          Pathway
    22.   A new 2.0m wide pathway must be constructed along the frontage of the site to
          Vision Court and extended to the northern boundary of the adjoining lot to the south
          in accordance with the following requirements:
          a.   Be generally in accordance with the approved plans and in compliance with the
               higher order approval conditions and standard drawing IPWEAQ RS-065.
          b.   Footpath alignment must be amended where necessary to avoid conflict with
               any existing obstructions (eg electricity power pole).
          c.   All paths, driveways and uncovered parking areas must have a slip resistant
               surface.
          d.   Expansion and contraction joints must provide a flush finish. Installation of joints
               by saw cutting is preferred to ensure a smooth ride for cyclists.
          e.   The works must include any modifications to existing service covers to ensure
               the footpath finishes flush with all services and the like, so as not to create any
               pedestrian safety hazard.


                                                                                  Page 20 of 125
Log in to download the original file

2017-02-07 Planning and Environment Committee Agenda(PDF, 18MB).pdf · 19.2 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.