6.5 Access & Driveways
Driveways and areas for car turning are also to be provided in accordance with the Local Authority’s
requirements. Earthworks undertaken on sites to provide these areas are as important as the earthworks
required to create the building area.
6.6 Retaining Walls
All retaining walls over 1.0 metre in height, whether stand-alone or forming part of the proposed
residence, are to be engineer designed in accordance with AS4678‐2002 “Earth‐Retaining Structures”.
Drainage should also form part of the wall design, to remove surface and sub-surface water from behind
the wall.
For the design of retaining structures, the following parameters are considered appropriate: -
Angle of internal friction, φ = 36°
Coefficient of active earth pressure Ka = 0.26
Coefficient of passive earth pressure Kp = 3.85
At rest coefficient of earth pressure Ko = 0.41
Bulk density: 17 kN/m
3
It is proposed to construct a series of block retaining walls to the low side of the garage (and parts of the
residence) and backfill to create level building platforms. Any cut batters under the residence for future
storage areas or structures should be retained and engineer designed.
It is important to note that some ground movement is to be expected behind any soil retaining system,
including gravity retaining walls.
6.7 Foundations
All founding should be to homogeneous soil types, and based on the sub-soil profile, load bearing
elements are required to bear a minimum 2.5 to 3.0m below current ground levels, into the underlying
medium dense/dense SAND. The use of steel screw-in piers to achieve these depths is recommended and
is commonplace for building on these sites. Foundations are to be augmented by structural design.
6.8 Septic & Sullage Disposal
All effluent and sullage discharge should be in accordance with the relevant local authority. A reticulated
sewerage system exists for effluent disposal. All connections in this system are to be in strict accordance
with the Local Authority’s specifications.
GeoConsulting Pty Ltd
1/8 Denna St, Maroochydore, QLD, 4558. Phone: 5443 6622, Fax: 5479 1899, Email: [email protected] 12 | P a g e
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
REFERENCED DOCUMENT - MCU13/0146Related documentApplication case desk ↗
About this file
- File size
- 2.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.