Original source · versioned page text
Annex 13 - Schedule 3 - Prescribed Tidal Works
Attached to the e-mail DA Application - Noosa Oyster Project (2 of 3).
Coastal Protection and Management Regulation 2017
Schedule 3. Code for Assessable Development that is prescribed tidal works
Part 3 Performance outcomes and acceptable outcomes
Design, construction and safety - boat ramps and slip ways for private purpose
(s 5(2) outcome)
13.1 Prescribed tidal works that are a boat The design and construction of the boat ramp or slipway is Not applicable.
ramp or slipway for a private purpose are consistent with the following standards—
designed and constructed in a way to ensure (a) subject to paragraph (c), the walls at the edge of the Not a boat ramp or slipway.
they are structurally sound while also ensuring boat ramp or slipway penetrate into the earth at least
the safe movement of vehicles or persons 600mm below the surface of the land on which the boat
between the boat ramp or slipway and the ramp or slipway is located;
surface of the land on which the boat ramp or
slipway is located. (b) subject to paragraph (c), the surface of the boat ramp or
slipway is no more than 200mm above the surface of the
land on which it is located;
(c) if a relevant planning scheme standard is more stringent
than the standard mentioned in paragraph (a) or (b)—the
relevant planning scheme standard, to the extent it is more
stringent than the standard mentioned in paragraph (a) or
(b).
13.2 Prescribed tidal works that are a boat (s 5(2) outcome)
ramp or slipway for a private purpose are The design and construction of the boat ramp or slipway is Not applicable.
designed and constructed in a way to ensure consistent with the following standards—
the safe movement of vehicles or persons over (a) subject to paragraph (d), the upper surface of a boat Not a boat ramp or slipway. Not a private purpose.
the boat ramp or slipway. ramp or slipway has a width of—
(i) for a boat ramp or slipway with vehicle access—no
less than 3.6m; or
(ii) for a boat ramp or slipway without vehicle access—
no less than 3.0m;
(b) subject to paragraph (d), the whole upper surface of a
boat ramp or slipway is treated to prevent it from becoming
slippery by using any of the following methods—
(i) forming grooves over the surface, as close as
possible to 40mm wide, 20mm deep and 150mm apart,