Council archive · source document
09/1270 - Approved plans/Negotiated Decision Notice [As Published] · 132009.1270
Plans and drawings: the text below has words only, no drawings.
2009/1270 Landscaping 5. Existing trees on the site and within road reserves are to be retained, except where required to be removed due to building operations or the conduct of the approved use. In this regard, 5.1. the removal of vegetation shall not extend beyond 3 metres of the building footprint of the Detached House. 5.2. disturbed vegetation within the setbacks shall be regenerated in accordance with Council’s Landscaping Plants and Guidelines PSP 3 and as shown on the Landscape Plan & Existing Site Conditions WD22 Revision-A dated 6 November 2009. 5.3. screening vegetation consisting of native, endemic species shall be planted to the setback to the northern boundary in accordance with Council’s Landscaping Plants and Guidelines PSP 3. All other vegetation shail be protected from interference resulting from. clearing or construction activities by: 6.1. Clearly marking vegetation to be retained with flagging tape; ‘ 6.2. Installing protective fencing around the drip line of the vegetation; 6.3. Stockpiling, storage and vehicle parking occurs in already cleared areas and does not cause interference with vegetation; and : 6.4. Low impact construction techniques are used around vegetation to minimise interference with the vegetation. Cleared vegetation is to be suitably processed by one of the following methods and removed from the site: 7A. Processing through a woodchipper or shredder. The .e resulting mulch is to be stockpiled loose in heaps of less than 1000 cubic metres, less than 2.5 metres high with a minimum of 10 metres between edges of heaps. 7.2. Disposal for firewood. - 7.3.0 ° Disposal for landscaping purposes. © ‘ The applicant is advised that burning off is an unacceptable method of disposal. Landscape planting within 1.5 metres of the sewerage inspection opening.must be Council approved varieties and low growing when mature. Building Height. 10. The building height shall not exceed 8.0 metres above the natural’ ground level, finished ground level and 2 storeys. 41. A verification survey of the building is to be carried out by’a Licensed Surveyor and a certificate lodged with Council at completion of the work confirming compliance with the maximum allowable building height (8m) as required by the Plan of Development (No. 67) on plan ACA-1. / . . General - ol . 12. The development must be undertaken and operated in a manner that causes no detrimental effect upon the amenity of the neighbourhood by reason of the creation of excessive noise, lighting nuisance or other emissions. 43. The transportation of all materials to and from the site shall be undertaken in a manner such that no particle matter escapes onto a public road. All vehicles carrying materials either to or from the site shall be covered to prevent materials including dust being windblown from the vehicle. Sof tt
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/1270 - Approved plans/Negotiated Decision Notice [As Published]Related documentApplication case desk ↗
About this file
- File size
- 865 KB (small file)
- File type
No other editions are linked here.