98 [Council will permit only one (1) metered water connection to be Refer to Water Plans
provided from the existing 150mm Council water main, along (C1-05)
|Aima Way in the Viridian Noosa Site, to service the development.
|A separate metered connection from the Council main in Aitunga
Heights will be permitted to service the separate allotment
accessed from Attunga Heights.
99 |The points of sewer discharge from the site into the existing Refer to Sewer Plans
Council system in Alma Way shall be to the standards and (C1-04)
requirements of Council's Planning Scheme Policy PSP6 —
Engineering Design Standards Water & Sewerage. The points of
discharge shall be a minimum of 20 metres from the nearest
house connection branch.
100 {Any internal sewerage pump station shall be constructed to the Refer to Sewer Plans
standards and requirements of Council's Planning Scheme Policy, (C1-04)
PSP6 — Engineering Design Standards Water & Sewerage Water
& Sewerage Capital Works Manager and shall include
magnesium hydroxide dosing to minimise odour from rising main
discharge.
101 |Any modifications to existing sewers required to accommodate Refer to Sewer Plans
pump flows including but not limited to poly-tined manholes, gas (C1-04) for external
check manholes and boundary traps shail be constructed at the works
applicant's expense.
102 |Concept master plans to be submitted indicating the location of Refer to Water and
the proposed sewerage pump station(s), sewer main and water Sewer Plans
supply infrastructure for preliminary approval prior to lodgement
of plans for Operational Works.
These plans are to include but not be limited to — location of
sewerage pump stations, rising mains, gravity sewers and water
mains, Plans are also to indicate area to be disturbed by
‘construction, method of crossing creek and methods to be utilised
to stabilise slopes and batters.
Sewer Mains
103 |The site shall be connected to Council's existing sewerage Refer to Water and
reticulation systems and be constructed in accordance with Sewer Plans
Council's standards and requirements at no cost to Council.
Town Water Supply
404 |The site shall be connected to Council's existing town water Refer to Water Plans
supply and be constructed in accordance with Council's (C1-05)
standards and requirements at no cost to Council.
105 |Fire hydrants are to be provided throughout the development in Refer to Water Plans
accordance with Council Engineering Design Standards and in (C1-05)
accordance with Queensland Fire Service Standards.
Service Easements
106 |Aregistered easement shall be created over the zone of influence Easements to be
of all sewers within the subject site and over those parts of the
subject site that are impacted upon by sewers on any adjoining
sites. The easements shall generally be parallel to and centred
over the sewer main and be equivatent in width to twice the depth
ta invert level of the sewer at the deepest point within the
allotment (measured from the finished surface) and be no less
than 3.0m wide. In this regard a licensed surveyor shall
accurately locate all sewer mains and determine the necessary
width of the easement, which shall be shown on any plans
submitted for Operational Works / Building Works approval. To
this extent the surveyor shall certify that the sewer and the zone of|
influence is wholly contained within the easement to be created.
located following
installation of services.
FAPROJECTS 20071078217 - Attunga Heights Development Approval (mwg)\06B217 - 0712085 - prk - Condition compliance matrix.xds
14
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2555 - Operational Works - Drainage Stormwater Vegetation [As Published]Related documentApplication case desk ↗
About this file
- File size
- 14.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.