Original source · versioned page text
Compiled Plans & Documents OPW18-0342 02
Bushfire Constraint Assessment – Peer Review
BlueCare, Sunrise Beach
that part of the land least on land determined as low bushfire threat of bushfire attack.
affected by the bushfire risk by a site specific bushfire hazard
hazard; and assessment.43
b) fire mitigation methods are AND
used that are adequate for
the Potential Bushfire S10.3 Additional lots are not created
Hazard rating of the
individual site, having regard where their only vehicular access
to – route is through a Medium or High
i. vegetation type; Bushfire Hazard area shown on
ii. slope;
iii. aspect; overlay maps OM1.4-OM9.4
iv. on-site and off-site fire
hazard implications of the
development;
v. bushfire history;
vi. conservation values of the
site; and
vii. ongoing maintenance.
Firebreaks and fire access S11.1 Firebreaks are provided by— An APZ equivalent to BAL-29 will
tracks a) a cleared road reserve not less be provided between the
O11 Firebreaks or fire than 20m wide located around the proposed development and any
access tracks provide— perimeter of the subdivision, identified bushfire hazard.
a) adequate access for fire between the created lots and
fighting and other emergency surrounding vegetated lands;
vehicles; and
b) adequate width to OR
minimise the risk of fire b) fire access tracks (may be in the
crossover. form of an access easement)
between the created lots and
surrounding vegetated lands that—
i. are a minimum cleared width of
6m;
ii. have a formed pavement;
iii. have access at each end and in
other locations where necessary;
iv. have passing areas and turning
areas;
v. have clearly identified access
points for emergency vehicles; and
vi. are located on public land or
within access easements that are
granted in favour of the Sunshine
Coast Regional Council and the
Queensland Fire and Rescue
Service44.
S12.1 Culs-de-sacs or no-through No culs-de-sacs are used within
O12 Roads provide for the roads are not used in the street the street networks.
network unless— Roads Will have a maximum
safe and effective evacuation grade of less than 12.5%
of users of premises and a) a perimeter road reserve with a
access by Emergency minimum reserve width of 20m and
services. a formed width of cul-de-sacs or no-
through roads are provided with fire
trails or access easements, capable
of being navigated by conventional
vehicles, that link to through roads
(see Figures 13.3 and 13.4);
AND
PR132938; Final / October 2016 Page 15
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Compiled Plans & Documents OPW18-0342 02.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.