                                                                                                      Proposed Controls
Activity          Risk                                                                                                                                                                         Responsible Person




                                Risk
                                                                                                                                                                                    Risk




                                             HOC




                               Initial
                               Rating
                                                                          (1/Elimination 2/Substitution 3/Isolation 4/Engineering 5/Administration 6/PPE)




                                                                                                                                                                                  Residual
           Building masonry   EXTREME    5         Maximum unsupported wall heights:                                                                                                         Site Management
           walls more than
           recommended                                                                                                                                                                       Contract Partner
                                                                                                      Maximum unsupported wall height (mm)
           heights without
           bracing                                                Width of brick /
                                                                   block (mm)           Low to moderate winds (0-             Fresh winds
                                                                                        29 km/h)                              (30-39 km/h)

                                                                                        Single skin        1500               Single skin        750
                                                                              90
                                                                                        cavity             2100               cavity             1050
                                                                 Brick
                                                                                        Single skin        1800               Single skin        900
                                                                              110
                                                                                        cavity             2500               cavity             1250

                                                                              90        1050                                  525

                                                                 Block        140       1600                                  800

                                                                              190       2500                                  1250

           Wall collapse      EXTREME    3         Masonry bracing methodologies to align with the masonry wall guide.                                                                       Site Management
                                                                                                                                                                                             Contract Partner




                                                                                                                                    Project Hazard/Risk Assessment / Page 125 of 160

Used in these records

About this file

File size
836 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Project Hazard_Risk Assessment Ozcare Noosa RACF 23-042024 STP24-0253 Application for Operational Works Fire Trail - 80 Cooyar Street Noosa Heads - Copy.pdf · 836 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.