Council archive · source document
Project Hazard_Risk Assessment Ozcare Noosa RACF 23-042024 STP24-0253 Application for Operational Works Fire Trail - 80 Cooyar Street Noosa Heads - Copy · OPW24/0118
Proposed Controls
Activity Risk Responsible Person
Risk
Risk
HOC
Initial
Rating
(1/Elimination 2/Substitution 3/Isolation 4/Engineering 5/Administration 6/PPE)
Residual
Building masonry EXTREME 5 Maximum unsupported wall heights: Site Management
walls more than
recommended Contract Partner
Maximum unsupported wall height (mm)
heights without
bracing Width of brick /
block (mm) Low to moderate winds (0- Fresh winds
29 km/h) (30-39 km/h)
Single skin 1500 Single skin 750
90
cavity 2100 cavity 1050
Brick
Single skin 1800 Single skin 900
110
cavity 2500 cavity 1250
90 1050 525
Block 140 1600 800
190 2500 1250
Wall collapse EXTREME 3 Masonry bracing methodologies to align with the masonry wall guide. Site Management
Contract Partner
Project Hazard/Risk Assessment / Page 125 of 160