Original source · versioned page text
Attachment C- REC14.0005 Negotiated Decision Notice
REC14/0005 UNITYWATER Important Advisory Note - The following Unitywater conditions are applied in accordance with the Chapter 4c, part 7 and sections 135 and 140(c) South East Queensland (Distribution and Retail) Restructuring Act 2009 and Unitywater’s Interim Connections Policy. The conditions below form part of a water connection aspect which are taken to be a water approval for a staged connection. You are entitled to appeal against the water connection aspects of this application in accordance with section 99BRAY and Chapter 4c, part 4, Divisions 1 and 2 of the South East Queensland (Distribution and Retail) Restructuring Act 2009. Unitywater can be contacted as follows: Phone: 1300 0 Unity (1300 086 489) Email: [email protected] Web: www.unitywater.com 21. Reticulated water must be provided to each lot in the development. This must include: (a) Ensuring that existing internal water pipes are wholly contained within the lot they will serve. (b) An approved water meter for each lot in accordance with Unitywater and SEQ Standard Drawings. (c) Provision of a water service to service proposed all lots in accordance with Unitywater and SEQ Standard Drawings. (d) Provision of a pipeline conduit under Gateway Drive in accordance with Unitywater and SEQ Standard Drawings. (e) An approved 150mm diameter water service connection to each lot in accordance with Unitywater requirements. 22. Water meters must be located on alternative boundaries to electrical pillars. 23. Reticulated sewerage must be provided to each lot in the development. This must include: (a) Ensuring existing sewer house drains are wholly contained within the Lot they will serve. (b) Provision of sewerage infrastructure to the property boundaries of Lot 103. 24. Written approval to enter and construct must be obtained from the owners of properties through which external sewers will traverse, and be submitted with lodgment of the associated development application for Operational Works. 25. Easements of between 3 and 10 metres must be provided over all Unitywater sewers located within property boundaries in accordance with the SEQ standards. Easements shall be centred over the pipe. Easement terms shall be the most current registered dealing held by the Department of Natural Resources & Mines and shall not be altered or amended. 26. Written approval to enter and construct must be obtained from the owners of properties through which external watermains will traverse. This must include approval for an easement over the mains, and be submitted with lodgment of the associated development application for Operational Works. 27. A minimum clearance of 1.5 metres must be maintained between Unitywater sewers and proposed building envelopes, buildings and other structures. Page 5 of 10
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original