Attachment 2 - Negotiated Decision Notice MCU16-0130

Attached to the e-mail Change to DA - MCU16/0130.01.msg.

of 14

Page text shows just the words. Original shows the document exactly as it was published.

Noosa Council documents




                                                                                                     MCU16/0130

                      Waste Disposal
               24.    The developer must provide waste storage and disposal facilities in accordance with
                      Planning Scheme Policy No. 9 “Waste Management Multi-Dwellings and Commercial
                      and Industrial Premises”. The facilities must include an external impervious area
                      correctly sized for all refuse and recycling containers and suitably screened from public
                      places and neighbouring properties. A bin wash area is required with a cold-water tap,
                      hose and drain outlet connected to sewer, via a bucket trap. The drain outlet must be
                      designed to prevent storm water entry to the sewerage system. This can be achieved
                      with a nib wall 50mm high and up to 700mm x 700mm wide (max 0.5m²), or alternatively
                      the waste area can be roofed, or any other design approved by Council.
               25.    Refuse containers must be provided in accordance with the requirements of the
                      Environmental Protection (Interim Waste) Regulation 1996 and (Waste Management)
                      Regulation 2000, for the storage and collection of refuse.
               ENGINEERING
                   Frontage Works
               26.    The existing masonry planter boxes located adjacent to the Eumundi Noosa Road
                      frontage must be removed and/or relocated to be wholly within the subject site
                      Site Access and Driveways
               27.    A sealed access driveway must be provided from Eumundi Noosa Road to all parking
                      and manoeuvring areas of the development. The works must be undertaken in
                      accordance with an Operational Works approval and must include in particular:
                      a.      a new driveway crossover adjacent to the northern site boundary. The driveway
                              must be in accordance with Council’s standard drawing number RS-051 and
                              located to not interfere with the existing access to the adjoining property.
                      b.      the northern driveway must be for left turn entry only.
                      c.      the southern driveway must be for left turn exit only.
                      d.      internal driveways between the entrance driveway, the carparking areas and the
                              exit driveway.
                      e.      suitable safety measures, including warning signage, to improve driver awareness
                              of pedestrians and enhance pedestrian safety. Warning signage must be provided
                              near the exit driveway to warn motorists of pedestrian movement along the
                              frontage street.
                      Car Parking
               28.    A minimum of 16 car parking spaces must be provided and marked on the site and
                      made available and accessible at all times while the use is open for business. The works
                      must be undertaken in accordance with an Operational Works approval and must
                      include in particular:
                      a.      pedestrian routes between the carparking area and the business use.
                      b.      dimensions, crossfalls and gradients in accordance with Australian Standard
                              AS/NZS2890.1:2004: Parking Facilities.
               29.    All car parking areas and access driveways must be maintained exclusively for vehicle
                      parking and manoeuvring and kept in a tidy and safe condition at all times.
               30.    Directional signage must be provided to direct visitors and customers to the car parking
                      spaces provided on site.




                                                                                                Page 5 of 11



Document Set ID: 20586157
Version: 6, Version Date: 24/05/2018                                                                Print Date: 24 May 2018, 11:22 AM
Log in to download the original file

Attachment 2 - Negotiated Decision Notice MCU16-0130.pdf · 1.9 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.