GENERAL COMMITTEE MEETING AGENDA   17 OCTOBER 2016




                                      Page 35 of 67

GENERAL COMMITTEE MEETING AGENDA                                                                    17 OCTOBER 2016

               (d)     The rainwater downpipe to the north of the landing to the east of the sitting area, has a
                       breakage at the bottom of the downpipe. The rainwater downpipes should be checked
                       individually in order to ascertain their current condition and where there are breakages or
                       blockages they should be either repaired or replaced.

               (e)     The rainwater downpipe to the eastern end of the southern external wall of the original hall,
                       in the area where the external cladding steps up to the southern side of the kitchen is
                       broken and will require reinstating.
               (f)     The top of the various vent pipes to the sewer/ drains to the building, are in need of
                       reassessing and the appropriate stays to be fitted especially, but not limited to the fibrolite
                       vent pipes.
                       The top of the vent pipes, are in need of the appropriate cowl to be fitted.
               (g)     The southern end of the bargeboard to the northern gable to the western side of the hall is
                       exhibiting the effects of fungal decay to the top of the bargeboard, in the area where the
                       planted trim used to be located.
                       This will require addressing at the time the planted trim is refitted and the gable roll is
                       reinstated.

               (h)     The painted finish to the western fascia is in need of reinstating especially but not limited to
                       the area of fascia above the third set of windows in from the northern end of the western
                       side of the building.
                       The cause appears to have been accelerated by the leak in the join to the rainwater gutter
                       over this area. This will be addressed at the time the rainwater gutter is replaced or
                       repaired.

               3.005   INTERIOR OF THE BUILDING.

              (i)      ENTRY/FOYER.
               (a)     The glazing to the door between the entry/foyer and the main hall area, should be
                       reassessed with a view to installing an appropriate glass in these doors, especially given the
                       amount of people that may pass through this doorway.
              (ii).    MEMORABILIA ROOM, PROJECTOR ROOM / LOFT AREA & TICKET ROOM:
               (a)     The inside of the Memorabilia Room, Projector Room and Storage Loft area were only
                       partially accessible due to the goods stored in these areas at the time of inspection.
                       To ascertain the exact condition of these areas, will require reinspection to be carried out
                       after the goods have been removed from these areas.

               (b)     The ceiling sheeting to the projector room has what appears to be Caneite or similar, that
                       has been applied over asbestos cement sheeting.
                       It is brought to your attention that there are holes and other damage to the asbestos
                       cement sheeting to the ceiling and as such, this asbestos cement sheeting, should be
                       removed or otherwise made safe.

                                                                                                            11

                                                                                                           Page 35 of 67
Log in to download the original file

2016-10-17 General Committee Meeting Notes(PDF, 11MB).pdf · 11.2 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.