Original source · versioned page text
10. APP E. Traffic Impact Assessment Report
Attached to the e-mail MCU14/0102 Development application Part 2 of 4 App E Traffic Report, App F Landscape Plan.
Original PDF page 18, section 1. The text section number identifies this passage in the reader.
PEKOL TRAFFIC & TRANSPORT early mornings and late afternoons. However, the retail use (hardware store) would experience peak parking demand during the middle of the day and on weekends. On this basis, the proposed provision is considered is sufficient to accommodate the anticipated peak parking demand. 3.3.3 Design The layout and provision of on-site car parking is generally consistent with the requirements of Australian Standard AS2890.1:2004 Parking Facilities Part 1: “Off-Street Car Parking” in terms of bay dimensions, aisle widths, vehicle circulation and manoeuvring. This is typified by: == 2.6m x 5.4m vehicle parking spaces == 1.2m x 2.5m motorcycle parking spaces == appropriately dimensioned PWD spaces with adjacent shared space = parking aisles of 6.2m wide or greater 3.3.4 Impact on On-Street Parking The development proposal will result in the loss of two on-street car parking bays along the Eumundi Road frontage. Subject to input from Noosa Council, the proposed access arrangements would provide scope to retain four on-street bays between the site entry and exit driveways 3.4 Queuing It is estimated that the site would be able to accommodate at least 16 vehicles waiting in queue to fill up with fuel (not including those parked at the pumps).We estimate that there is also queuing provision for three vehicles to wait between the site boundary and the first internal conflict point associated with the parking area adjacent to the retail (hardware) / industrial uses. This queuing provision is considered appropriate for the number of on-site parking spaces (ie 64 spaces) and fuel pump berths, and complies with the Australian Standard AS2890.1. 3.5 Servicing An on-site loading / refuse collection area is proposed for the service station and restaurant / cafe uses. The Noosa Plan does not specify a design vehicle for this type and size of development. However, this service area could accommodate a 12.5m heavy rigid vehicle (HRV) without obstructing the operation of the fuel court. This loading area is in addition to on-site provisions for fuel deliveries. The swept path of a petrol tanker accessing and egressing the site is presented in Figure 3.1 and is also attached to this report. The largest vehicle type expected to serve the retail (hardware) / industrial uses would be a heavy rigid vehicle (HRV). Recessed loading areas are proposed for each unit capable of accommodating an HRV. —_—__—_— P:\2014-15\15-067 LIONEL DONOVAN DRIVE, NOOSAVILLE\REPORTS\139 EUMUNDI ROAD, NOOSAVILLE TIA REPORT.DOCX 14
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.