Original source · versioned page text
Part 14 Codes PIP to LGIP 8 June 2018
Attached to the e-mail Operational Works Application OPW20/0114 - Email 2 of 4 - Civil Plans - Community Titles Scheme Statement - BUP - Part 14 Assessment Benchmarks - 4 Portside Crt, Noosaville.
Attached to the e-mail RE_ Proprietary Products & Compliance with SQUIDEP.eml, inside BP Noosaville - overview of proposed stormwater quality strategy related discussions.msg.
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
Including amendments 8 June 2018
Division 20—Water Sensitive Design Code
The Noosa Plan
14.155 Water Sensitive Design Code
The provisions in this division comprise the Water Sensitive Design Code. They are—
compliance with the Water Sensitive Design Code (section 14.157);
overall outcomes for the Water Sensitive Design Code (section 14.158);
specific outcomes and probable solutions for the Water Sensitive Design Code
(section 14.159).
14.156 Compliance with the Water Sensitive Design Code
Development that is consistent with the specific outcomes in section 14.159 complies
with the Water Sensitive Design Code.
14.157 Overall outcomes for the Water Sensitive Design Code
14.157.1 The overall outcomes are the purpose of the Water Sensitive Design Code.
14.157.2 The overall outcomes sought by the Water Sensitive Design Code are to ensure that—
a) development is designed, constructed and operated in a manner that contributes to, and does
not impede, long term attainment of relevant Environmental Values and Water Quality
Objectives as specified in the Environmental Protection Policy 2009;
b) development avoids adverse impacts on downstream ecosystems, properties and
infrastructure due to changes to stormwater flow, water quality or ecosystem health;
c) stormwater conveyance channels use natural channel design principles to convey external
catchment stormwater through development and support landscape, passive recreation and
ecological values;
d) urban development captures and utilises run-off from appropriate areas for use on site; and
e) water reuse facilities have no adverse impact on the quality of the town mains water.
14.158 Specific outcomes, acceptable solutions and probable solutions for
the Water Sensitive Design Code
The specific outcomes sought for the Water Sensitive Design Code are included in
column 1 of Table 14-61. Probable solutions for code assessment development are
included in column 2 of Table 14-61.
Table 14-61
column 1 column 2
Specific Outcomes Probable solutions (if code assessment)
Maintenance of environmental values and water
quality objectives S1.1 Development meets the applicable
O1 Downstream ecosystems, properties and performance outcomes of the State Planning
infrastructure are not adversely impacted by either Policy Appendix 2 SPP Code: Water
changes to flow, water quality or ecosystem health Quality;
caused by development. AND
S1.2 Design and construction methods for
stormwater quality treatment assets are in
accordance with Healthy Waterways Water
14-160
Watercourses Works Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.