Part 14 Codes PIP to LGIP 8 June 2018

Attached to the e-mail Operational Works Application OPW20/0114 - Email 2 of 4 - Civil Plans - Community Titles Scheme Statement - BUP - Part 14 Assessment Benchmarks - 4 Portside Crt, Noosaville.

Attached to the e-mail RE_ Proprietary Products & Compliance with SQUIDEP.eml, inside BP Noosaville - overview of proposed stormwater quality strategy related discussions.msg.

of 192

Page text shows just the words. Original shows the document exactly as it was published.

Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.

                  column 1                                           column 2




                                                                                                                           Including amendments to 8 June 2018
              Specific Outcomes                       Probable solutions (if code assessment)




                                                                                                          The Noosa Plan
                                                    Figure 14-38




                                                    AND
                                                    S12.8 Walkways serving jetties have at least
                                                    one rigid handrail fitted and the walkway is a
                                                    minimum width of 750mm and a maximum width
                                                    of 1.5m where—;
                                                     a) the walking surface of the jetty is
                                                           constructed level with the top of the
                                                           revetment wall;
                                                     b) water reticulation systems are fitted with a
                                                           mechanical backflow prevention device;
                                                           and
                                                     c) electrical reticulation systems carrying
                                                           electricity in excess of 24 volts are not to
                                                           extend beyond the revetment wall;
                                                     AND
                                                     S12.9 Any lower-level platform, or siding, along
                                                     the jetty walkway has a maximum width of
                                                     500mm and does not exceed 2m2 and does not
                                                     interfere with the prolongation of boundaries as
                                                     indicated by Probable solutions 11.1-11.3;
O13 Pontoons and boat ramps are not
constructed in Noosa Waters Estate.                 S13.1 No solution provided

14.169 Boat lifting devices
O14 Boat lifting devices are only constructed in    S14.1 Boat lifting devices are only located in
the absence of a boat ramp and are designed         conjunction with an approved jetty where
and located to—                                     a) the boat lifting device does not extend into
a)    ensure that unacceptable risks to personal          the watercourse beyond the end of the
      and public safety are unlikely to be                approved jetty;
      caused;                                       b) the boat lifting device is no greater than 4m
b)    avoid cluttering of the watercourse;                in width or for a jetty hoist 2m in width;
c)    ensure that visual amenity of the             c) the boat lifting device is located adjacent to
      foreshore and watercourse is maintained;            walkway to the jetty and is generally
      and                                                 perpendicular to the revetment wall;
d)    ensure the structure integrity of the works   d) the boat lifting device is not located on the
      are maintained and not compromised.                 jetty head; and
                                                    e) the outermost projection of the boatlifting
                                                          device of jetty hoist is setback a minimum
                                                          of 1m from the prolongation of the
                                                          boundaries;
                                                    AND
                                                    S14.2 Only one boat lifting device and a jetty
                                                    hoist per jetty;


                                               14-171
                                       Watercourses Works Code
Log in to download the original file

Part 14 Codes PIP to LGIP 8 June 2018.pdf · 3.2 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.