Table 14-24 — For All Residential Uses
Including amendments to 8 June 2018
The Noosa Plan
column 1 column 2
Specific Outcomes Probable solutions (if code assessment)
14.46 Effects of use
Electricity supply infrastructure
O1 The development does not adversely S1.1 No solution provided
impact on existing or future electricity supply
infrastructure;
AND
O2 All uses and works maintain an adequate S2.1 Development for uses adjacent to or
safe distance from electrical infrastructure within 50m of an existing electricity substation
including substations, overhead powerlines, incorporates noise attenuation measures to
power poles and transformers. mitigate noise impacts;
AND
S2.2 Buildings and structures (including
swimming pools, sheds, tennis courts or
outbuildings) are not constructed under
overhead electricity transmission lines, or
within electricity easements;
AND
S2.3 A minimum separation distance is
maintained from the electricity transmission
line to the closest boundary of habitable
buildings and child activity areas, as follows—
a) 20m for transmission lines up to 132kV;
b) 30m for transmission lines between
133kV and 275kV; and
c) 40m for transmission lines greater than
275kV.
Water supply and conservation
S3.1 & S4.1 For a Class 1 building18 other than
O3 On-site water storage is designed and
a Detached house , outside a reticulated
operated to support the efficient use of water;
water service area, a rainwater tank is to be
installed with the following minimum storage
AND
capacities—
O4 On-site water storage is adequate for a) Where no more than 3 bedrooms –
occupants every day use and fire fighting 45,000 litres; or
purposes. b) Where more than 3 bedrooms –
60,000 litres;
AND
c) There is to be on the lot a dam,
swimming pool or water tank
accessible for use by the fire brigade
that contains at least 5,000 litres of
water.
Editor’s note:
The 5,000 litres required can be included
within the water required in S3.1 or S4.1
providing it is accessible for the purpose of fire
fighting at all times and not used for other
domestic purposes.
18
Class 1 Buildings are defined under the Building Code of Australia
14-46
Residential Uses Code