column 1 column 2
Including amendments to 8 June 2018
Specific Outcomes Probable solutions (if code assessment)
The Noosa Plan
Erosion and sediment control
O5 Development does not cause erosion or No solution provided.
result in transport of sediments off-site.
Editor’s note:
Persons undertaking development, including
building work, are required under the Environmental
Protection (Water) Policy 1997 (EPP) to ensure that
sediment and other material including building
waste, sawdust, concrete, cement or paint are not
deposited or released into a roadside gutter,
stormwater drain or waterway, or into a place where
it could reasonably be expected to move or be
washed into a roadside gutter, stormwater drain or
waterway and are not washed from the site.
Council enforces the EPP and penalties may apply.
Safety and security
O6 For Multiple Housing Types 2, 3 and 4, S6.1 The building entrance is clearly
buildings and outdoor spaces are designed to identifiable and visible from the street, footpath
protect the personal security and safety of and driveway;
residents by allowing for natural surveillance. AND
S6.2 The internal path network has clear
sightlines to the dwelling entry and street
access points;
AND
S6.3 Visitors have direct access to the
entrance without passing through private
outdoor living areas.
Emergency access
O7 For Multiple housing Type 3, 4 & 5, site No solution provided
design and layout ensures efficient access and
egress for emergency vehicles.
Basement drainage
O8 Buildings and access works are designed S8.1 Enclosed car parking and manoeuvring
and sited to protect persons and property in the areas are constructed at a level that permits
event of a flood and power failure. the parking area to drain from the site by
gravity means, without the need for
mechanical pumping.
Separation of incompatible uses
O9 Development is designed to minimise noise S9.1 Bedroom windows are at least 3m away
carrying between dwelling units or from shared driveways or carparking areas of
accommodation units by locating noise sensitive adjacent dwelling units or accommodation
spaces such as bedrooms away from noise units.
generating areas of the development, such as
carparking areas or mechanic plant and
equipment or recreational facilities.